Calibrating the Six-Port Reflectometer Using a Matched Load And Four Unity-Reflection Standards (Part 2)
dc.contributor.author | Bilik, V. | |
dc.coverage.issue | 2 | cs |
dc.coverage.volume | 1 | cs |
dc.date.accessioned | 2016-05-09T10:47:16Z | |
dc.date.available | 2016-05-09T10:47:16Z | |
dc.date.issued | 1992-12 | cs |
dc.description.abstract | A convenient and exact method of using a sliding load to the calibration of the single six-port reflectometer is described. Neither reflection coefficient nor positions of the sliding load settings need be known. Reflection coefficient of the load is not limited to small values. No numerical iterations are involved in the calibration. | en |
dc.format | text | cs |
dc.format.extent | 2-8 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 1992, vol. 1, č. 2, s. 2-8. ISSN 1210-2512 | cs |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/58634 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | http://www.radioeng.cz/fulltexts/1992/92_02_01.pdf | cs |
dc.rights | Creative Commons Attribution 3.0 Unported License | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.subject | Six-port reflectometer | en |
dc.subject | calibration | en |
dc.title | Calibrating the Six-Port Reflectometer Using a Matched Load And Four Unity-Reflection Standards (Part 2) | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1