Effects of Micro-Scale Mobility and Beam Misalignment in On-Body mmWave Systems
dc.contributor.author | Ali, Asad | cs |
dc.contributor.author | Galinina, Olga | cs |
dc.contributor.author | Hošek, Jiří | cs |
dc.contributor.author | Andreev, Sergey | cs |
dc.coverage.issue | 3 | cs |
dc.coverage.volume | 28 | cs |
dc.date.issued | 2024-01-02 | cs |
dc.description.abstract | Wearable devices positioned on a human body have challenges in millimeter-wave (mmWave) communication due to micro-scale mobility, such as subtle shakes and rotations. These movements can compromise the radio link performance. It may be problematic for high-rate immersive applications, where this can lead to substantial degradation in the user’s quality of experience. In this letter, we propose a framework to quantify the impact of micro-scale mobility and beam misalignment on the performance of on-body mmWave links. Our findings reveal that for varying levels of beam misalignment, it is possible to adjust the antenna half-power beamwidth to enhance the data rates. | en |
dc.format | text | cs |
dc.format.extent | 682-686 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | IEEE COMMUNICATIONS LETTERS. 2024, vol. 28, issue 3, p. 682-686. | en |
dc.identifier.doi | 10.1109/LCOMM.2023.3349349 | cs |
dc.identifier.issn | 1558-2558 | cs |
dc.identifier.orcid | 0000-0002-8382-9185 | cs |
dc.identifier.other | 187091 | cs |
dc.identifier.researcherid | B-1780-2010 | cs |
dc.identifier.scopus | 37031030200 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/245476 | |
dc.language.iso | en | cs |
dc.publisher | IEEE | cs |
dc.relation.ispartof | IEEE COMMUNICATIONS LETTERS | cs |
dc.relation.uri | https://ieeexplore.ieee.org/document/10379591 | cs |
dc.rights | Creative Commons Attribution 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1558-2558/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | Beam misalignment | en |
dc.subject | micro-scale mobility | en |
dc.subject | personal wearable devices | en |
dc.subject | millimeter-wave communication | en |
dc.title | Effects of Micro-Scale Mobility and Beam Misalignment in On-Body mmWave Systems | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-187091 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:42:38 | en |
sync.item.modts | 2025.01.24 17:32:08 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikací | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Effects_of_MicroScale_Mobility_and_Beam_Misalignment_in_OnBody_mmWave_Systems.pdf
- Size:
- 2.81 MB
- Format:
- Adobe Portable Document Format
- Description:
- file Effects_of_MicroScale_Mobility_and_Beam_Misalignment_in_OnBody_mmWave_Systems.pdf