Novel voltage Multiplier/Divider-based active square law detector for heartbeat measurement
dc.contributor.author | Šotner, Roman | cs |
dc.contributor.author | Polák, Ladislav | cs |
dc.contributor.author | Jeřábek, Jan | cs |
dc.contributor.author | Langhammer, Lukáš | cs |
dc.contributor.author | Freeborn, Todd | cs |
dc.coverage.issue | 2 | cs |
dc.coverage.volume | 226 | cs |
dc.date.issued | 2024-02-28 | cs |
dc.description.abstract | This paper describes a novel active voltage detector that is capable of processing analog signals with levels from units of mV up to 250 mV. An advantage of the proposed circuit is that the relationship between output voltage and input level is not linear but quadratic, which increases the sensitivity when processing low-level signals. The presented solution has tuning parameters for correction or intentional shift of internal DC offset and electronic control of the output signal gain level. The application example presents detection of beats per minute (BPM) in the range of 6-300 BPM, which corresponds to a frequency range of 0.1-5 Hz. The advantage of the presented solution is that the output of the circuit is directly a digital signal compatible with TTL levels, so there is no need for any analog to digital converter to produce a digital signal for further processing. | en |
dc.description.embargo | 2026-01-26 | cs |
dc.format | text | cs |
dc.format.extent | 1-12 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | MEASUREMENT, Journal of the International Measurement Confederation (IMEKO) . 2024, vol. 226, issue 2, p. 1-12. | en |
dc.identifier.doi | 10.1016/j.measurement.2024.114145 | cs |
dc.identifier.issn | 0263-2241 | cs |
dc.identifier.orcid | 0000-0002-2430-1815 | cs |
dc.identifier.orcid | 0000-0001-7084-6210 | cs |
dc.identifier.orcid | 0000-0001-9487-5024 | cs |
dc.identifier.orcid | 0000-0002-2136-1601 | cs |
dc.identifier.other | 188348 | cs |
dc.identifier.researcherid | G-4209-2017 | cs |
dc.identifier.researcherid | E-3929-2018 | cs |
dc.identifier.researcherid | G-6453-2018 | cs |
dc.identifier.scopus | 21834721500 | cs |
dc.identifier.scopus | 36167253100 | cs |
dc.identifier.scopus | 23011945600 | cs |
dc.identifier.scopus | 56857453900 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/249344 | |
dc.language.iso | en | cs |
dc.publisher | ELSEVIER SCI LTD | cs |
dc.relation.ispartof | MEASUREMENT, Journal of the International Measurement Confederation (IMEKO) | cs |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0263224124000290?via%3Dihub | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
dc.rights.access | embargoedAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/0263-2241/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
dc.subject | Analog multiplier | en |
dc.subject | Beats per minute (BPM) | en |
dc.subject | Detector | en |
dc.subject | Heart rate | en |
dc.subject | Sensing readout | en |
dc.subject | Schmitt comparator | en |
dc.subject | Variable gain amplifier | en |
dc.title | Novel voltage Multiplier/Divider-based active square law detector for heartbeat measurement | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | acceptedVersion | en |
sync.item.dbid | VAV-188348 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:41:52 | en |
sync.item.modts | 2025.01.17 18:46:24 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav radioelektroniky | cs |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikací | cs |