Circuits for the Charge Push-through Electronics: Power Efficient Signal Processing Inside the Artificial Cochlear Implant
dc.contributor.author | Žák, Jaromír | cs |
dc.contributor.author | Hubálek, Jaromír | cs |
dc.contributor.author | Prášek, Jan | cs |
dc.contributor.author | Pekárek, Jan | cs |
dc.contributor.author | Svatoš, Vojtěch | cs |
dc.contributor.author | Hadaš, Zdeněk | cs |
dc.contributor.author | Dušek, Daniel | cs |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 168 | cs |
dc.date.accessioned | 2022-05-12T10:53:50Z | |
dc.date.available | 2022-05-12T10:53:50Z | |
dc.date.issued | 2016-09-04 | cs |
dc.description.abstract | This work deals with the new technique called Charge Push-Through technology which is more energy efficient than the currently used approaches. The new energy efficient design regarding utilization of emerging technology such as Energy harvesting (EH) power sources is very promising for future development of energy independent (zero-power) and nonobtrusive cochlear implant. This work presents the solution of Charge Push-Through circuits using the component level design of artificial cochlea. | en |
dc.description.abstract | V práci je popsána nová technika protlačení náboje, což je technika zpracování signálu s významným snížením spotřeby zařízení. Metoda protlačení náboje je slibnou technikou u perspektivních systémů se soběstačným napájením využívajících tzv. Energy Harvesting. Článek obsahuje rozbor a simulaci obvodů na součástkové úrovni. | cs |
dc.format | text | cs |
dc.format.extent | 1710-1713 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | Procedia Engineering. 2016, vol. 168, issue 1, p. 1710-1713. | en |
dc.identifier.doi | 10.1016/j.proeng.2016.11.496 | cs |
dc.identifier.issn | 1877-7058 | cs |
dc.identifier.other | 131436 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/204223 | |
dc.language.iso | en | cs |
dc.publisher | Elsevier | cs |
dc.relation.ispartof | Procedia Engineering | cs |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S1877705816338188 | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1877-7058/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
dc.subject | Artificial cochlea | en |
dc.subject | charge push through | en |
dc.subject | zero power system | en |
dc.subject | Kochleární implantát | |
dc.subject | protlačení náboje | |
dc.subject | autonomní systém | |
dc.title | Circuits for the Charge Push-through Electronics: Power Efficient Signal Processing Inside the Artificial Cochlear Implant | en |
dc.title.alternative | Elektronické obvody protlačení náboje: Výkonově efektivní zpracování signálu uvnitř kochleárního implantátu | cs |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-131436 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2022.05.12 12:53:50 | en |
sync.item.modts | 2022.05.12 12:14:55 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav mikroelektroniky | cs |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. oddělení-MEL-SIX | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1s2.0S1877705816338188main.pdf
- Size:
- 398.28 KB
- Format:
- Adobe Portable Document Format
- Description:
- 1s2.0S1877705816338188main.pdf