Rapid Characterization of Biomolecules’ Thermal Stability in Segmented Flow-Through Optofluidic Microsystem

Loading...
Thumbnail Image

Authors

Fohlerová, Zdenka
Hubálek, Jaromír
Podešva, Pavel
Otáhal, Alexandr
Neužil, Pavel

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Nature
Altmetrics

Abstract

Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (T) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470 nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA – SYBR Green I complex with a known melting temperature (TM) in a flow-through configuration without gradient to verify the functionality of proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to T of 2.31°C mm-1, determining the heat transfer time as 563 ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.
Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (T) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470 nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA – SYBR Green I complex with a known melting temperature (TM) in a flow-through configuration without gradient to verify the functionality of proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to T of 2.31°C mm-1, determining the heat transfer time as 563 ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.

Description

Citation

Scientific Reports. 2020, vol. 10, issue 1, p. 1-9.
https://www.nature.com/articles/s41598-020-63620-5

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO