Abstract

Degradation of the articular cartilage (AC) structure due to osteoarthritis significantly influences its friction and lubrication mechanisms. Injection with exogenous hyaluronic acid (HA) is one of the ways to slow down the progress of these changes. The present paper aims to determine the effect of HA on the friction and lubrication processes of the synovial joint model. The main emphasis is placed on the effect of HA molecular weight (MW) on the coefficient of friction (COF) and the interactions between HA and other constituents of synovial fluid (SF). Frictional measurements between the AC surface and the glass were performed with simultaneous in situ observation of the contact zone by fluorescence microscopy. Using this methodology, a decrease in AC COF with an increase in the fluorescence intensity emitted from contact with HA was observed, while the phenomenon was found to be MW-dependent. These findings demonstrate that high-MW HA is more effective within a resumption of healthy AC lubrication due to a better adhesion to the AC surface.
Degradation of the articular cartilage (AC) structure due to osteoarthritis significantly influences its friction and lubrication mechanisms. Injection with exogenous hyaluronic acid (HA) is one of the ways to slow down the progress of these changes. The present paper aims to determine the effect of HA on the friction and lubrication processes of the synovial joint model. The main emphasis is placed on the effect of HA molecular weight (MW) on the coefficient of friction (COF) and the interactions between HA and other constituents of synovial fluid (SF). Frictional measurements between the AC surface and the glass were performed with simultaneous in situ observation of the contact zone by fluorescence microscopy. Using this methodology, a decrease in AC COF with an increase in the fluorescence intensity emitted from contact with HA was observed, while the phenomenon was found to be MW-dependent. These findings demonstrate that high-MW HA is more effective within a resumption of healthy AC lubrication due to a better adhesion to the AC surface.

Description

Citation

Lubricants. 2023, vol. 11, issue 1, 15 p.
https://www.mdpi.com/2075-4442/11/1/12

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO