Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

dc.contributor.authorMlýnek, Petrcs
dc.contributor.authorMišurec, Jiřícs
dc.contributor.authorKoutný, Martincs
dc.contributor.authorFujdiak, Radekcs
dc.contributor.authorJedlička, Tomášcs
dc.coverage.issue2cs
dc.coverage.volume15cs
dc.date.issued2015-06-09cs
dc.description.abstractThe article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology.en
dc.description.abstractČlánek se zabývá popisem simulace frekvenční odezvy PLC kanálu a vstupní impedance pomocí lineárního časově invariantního systému. Dále jsou představeny dva možné způsoby výpočtu primárních parametrů. A na závěr je provedeno porovnání přenosových funkcí a ověření výsledků měřením.cs
dc.formattextcs
dc.format.extent64-71cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationMeasurement Science Review. 2015, vol. 15, issue 2, p. 64-71.en
dc.identifier.doi10.1515/msr-2015-0010cs
dc.identifier.issn1335-8871cs
dc.identifier.orcid0000-0002-8565-1587cs
dc.identifier.orcid0000-0002-5023-7757cs
dc.identifier.orcid0000-0002-8319-0633cs
dc.identifier.other114808cs
dc.identifier.scopus56610269000cs
dc.identifier.urihttp://hdl.handle.net/11012/201323
dc.language.isoencs
dc.publisherSlovak Academy of Sciencescs
dc.relation.ispartofMeasurement Science Reviewcs
dc.relation.urihttps://www.sciendo.com/article/10.1515/msr-2015-0010cs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 3.0 Unportedcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1335-8871/cs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cs
dc.subjectPower line communicationen
dc.subjectprimary parametersen
dc.subjecttime-invariant systemen
dc.subjecttransfer functionen
dc.subjectsimulationen
dc.subjectmeasurementen
dc.subjectDatová komunikace po silnoproudém vedení
dc.subjectprimární parametry
dc.subjectčasově invarientní systém
dc.subjectpřenosová funkce
dc.subjectsimulace
dc.subjectměření.
dc.titleAnalysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communicationen
dc.title.alternativeAnalýza a experimentální ověření primárních přenosových parametrů pro PLC komunikacics
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-114808en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:42:14en
sync.item.modts2025.01.17 18:47:11en
thesis.grantorVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikacícs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10.1515_msr20150010.pdf
Size:
312.34 KB
Format:
Adobe Portable Document Format
Description:
10.1515_msr20150010.pdf