Moisture diagnostic of a failured roof drainage situated behind a parapet wall and a subsequent condensate influence to a wooden construction

dc.contributor.authorRemeš, Josefcs
dc.contributor.authorBrzoň, Romancs
dc.contributor.authorPetříček, Tomášcs
dc.contributor.authorHorák, Jiřícs
dc.date.issued2016-12-22cs
dc.description.abstractThere are several possibilities how to deal with a roof drainage. From an architectonic point of view an improper and unsuitable system is chosen in a majority of cases which may be as a logical consequence the beginning of upcoming problems. One of these problems is typically connected with either a roof location near the parapet wall, or in the corner of a flat roof. Another one is generally represented by a roof drainage solution with a side inflow for the drainage system that goes through the parapet wall construction. This solution is represented by a useful space increase in a layout of the building and an installation of a rainwater drainage core is not necessary in such cases. In case more of negative effects accumulate, such as an improper thermal insulation quality or insufficient thickness of the thermal insulation, significant problems may appear hand in hand with using of the building. These problems are generally represented by a moisture appearance in the inflow area. What more, this is not always detected and a major cause can be determined very hardly. This article deals with possible solutions for the wooden construction failure caused by the moisture that may emerge as an improper inflow layout consequence.en
dc.description.abstractThere are several possibilities how to deal with a roof drainage. From an architectonic point of view an improper and unsuitable system is chosen in a majority of cases which may be as a logical consequence the beginning of upcoming problems. One of these problems is typically connected with either a roof location near the parapet wall, or in the corner of a flat roof. Another one is generally represented by a roof drainage solution with a side inflow for the drainage system that goes through the parapet wall construction. This solution is represented by a useful space increase in a layout of the building and an installation of a rainwater drainage core is not necessary in such cases. In case more of negative effects accumulate, such as an improper thermal insulation quality or insufficient thickness of the thermal insulation, significant problems may appear hand in hand with using of the building. These problems are generally represented by a moisture appearance in the inflow area. What more, this is not always detected and a major cause can be determined very hardly. This article deals with possible solutions for the wooden construction failure caused by the moisture that may emerge as an improper inflow layout consequence.en
dc.formattextcs
dc.format.extent1-7cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationMATEC Web of Conferences. 2016, p. 1-7.en
dc.identifier.doi10.1051/matecconf/20179301004cs
dc.identifier.isbn978-2-7598-9012-5cs
dc.identifier.orcid0000-0002-2951-9653cs
dc.identifier.orcid0000-0002-5158-5585cs
dc.identifier.orcid0000-0001-7847-9814cs
dc.identifier.other130793cs
dc.identifier.researcheridM-6451-2018cs
dc.identifier.researcheridIWU-3892-2023cs
dc.identifier.researcheridAAD-6381-2019cs
dc.identifier.scopus56067400000cs
dc.identifier.scopus57073703800cs
dc.identifier.urihttp://hdl.handle.net/11012/196439
dc.language.isoencs
dc.publisherEDP Sciencescs
dc.relation.ispartofMATEC Web of Conferencescs
dc.relation.urihttp://www.matec-conferences.org/articles/matecconf/abs/2017/07/contents/contents.htmlcs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectroofen
dc.subjectmoistureen
dc.subjectcondensateen
dc.subjectwooden
dc.subjectconstructionen
dc.subjectdrainageen
dc.subjectroof
dc.subjectmoisture
dc.subjectcondensate
dc.subjectwood
dc.subjectconstruction
dc.subjectdrainage
dc.titleMoisture diagnostic of a failured roof drainage situated behind a parapet wall and a subsequent condensate influence to a wooden constructionen
dc.title.alternativeMoisture diagnostic of a failured roof drainage situated behind a parapet wall and a subsequent condensate influence to a wooden constructionen
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-130793en
sync.item.dbtypeVAVen
sync.item.insts2025.10.14 14:14:58en
sync.item.modts2025.10.14 10:26:30en
thesis.grantorVysoké učení technické v Brně. Fakulta stavební. Ústav automatizace inženýrských úloh a informatikycs

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
matecconf_bd2017_01004.pdf
Size:
3.68 MB
Format:
Adobe Portable Document Format
Description:
matecconf_bd2017_01004.pdf