The influence of image processing of -CT images on mechanical behavior of mandibular trabecular bone structure using micro finite element method
dc.contributor.author | Šustková, Apolena | cs |
dc.contributor.author | Thomková, Barbora | cs |
dc.contributor.author | Zikmund, Tomáš | cs |
dc.contributor.author | Kaiser, Jozef | cs |
dc.contributor.author | Joukal, Marek | cs |
dc.contributor.author | Marcián, Petr | cs |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 43 | cs |
dc.date.issued | 2023-01-13 | cs |
dc.description.abstract | Computational modeling plays an important role in assessment of biomaterial structures, living tissue and their mechanical properties. Microstructure investigation of bone tissue needs high-level computational models based on -CT images. A crucial factor when creating a computational model is image processing using tissue segmentation. The most common method for segmentation is thresholding. Threshold value can influence the geometry model and mechanical response in the bone tissue. One of the aims of the work is to determine and analyze the apparent mechanical behavior of mandibular trabecular bone structure based on different threshold value. Another aim of this study is to assess its influence on strain intensity from a local point of view, namely on one specific trabeculae. Fifty-four computational models including detailed trabecular structure of mandible were created based on -CT images. The thresholding was observed to have a significant effect on mechanical behavior of the trabecular bone structure. | en |
dc.format | text | cs |
dc.format.extent | 276-281 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | Procedia Structural Integrity. 2023, vol. 43, issue 1, p. 276-281. | en |
dc.identifier.doi | 10.1016/j.prostr.2022.12.271 | cs |
dc.identifier.issn | 2452-3216 | cs |
dc.identifier.orcid | 0009-0005-1100-620X | cs |
dc.identifier.orcid | 0000-0003-2948-5198 | cs |
dc.identifier.orcid | 0000-0002-7397-125X | cs |
dc.identifier.orcid | 0000-0002-9458-9690 | cs |
dc.identifier.other | 185061 | cs |
dc.identifier.researcherid | G-9491-2014 | cs |
dc.identifier.researcherid | D-6800-2012 | cs |
dc.identifier.researcherid | E-7359-2017 | cs |
dc.identifier.scopus | 7402184758 | cs |
dc.identifier.scopus | 55156647700 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/244309 | |
dc.language.iso | en | cs |
dc.publisher | Elsevier | cs |
dc.relation.ispartof | Procedia Structural Integrity | cs |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S2452321622008344 | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/2452-3216/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
dc.subject | image processing | en |
dc.subject | trabecular bone structure | en |
dc.subject | thresholding | en |
dc.subject | µ-CT | en |
dc.subject | FEM | en |
dc.title | The influence of image processing of -CT images on mechanical behavior of mandibular trabecular bone structure using micro finite element method | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-185061 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:47:42 | en |
sync.item.modts | 2025.01.17 15:28:17 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta strojního inženýrství. ÚMTMB-odbor biomechaniky | cs |
thesis.grantor | Vysoké učení technické v Brně. Středoevropský technologický institut VUT. Pokročilé instrumentace a metody pro charakterizace materiálů | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1s2.0S2452321622008344main.pdf
- Size:
- 1.28 MB
- Format:
- Adobe Portable Document Format
- Description:
- file 1s2.0S2452321622008344main.pdf