Technology for Hot Spring Cooling and Geothermal Heat Utilization: A Case Study for Balneology Facility

Loading...
Thumbnail Image

Authors

Vondra, Marek
Buzík, Jiří
Horňák, David
Procházková, Michaela
Miklas, Václav
Touš, Michal
Jegla, Zdeněk
Máša, Vítězslav

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI
Altmetrics

Abstract

Reducing energy costs in Europe is more challenging than before due to extreme price increases. The use of local renewable energy sources is one way to contribute to this effort. In the case of spa resorts, the use of heat from hot springs for therapeutic baths is an option. It is necessary to cool down this thermal mineral water to a temperature acceptable to the human body. However, due to the high mineral content of this water, heavy fouling can be a problem for conventional heat exchangers. The purpose of this study is to identify the suitable cooling technology in terms of required cooling capacity and waste heat recovery capability. The cooling technology was selected on the basis of a literature search. A pilot cooling unit consisting of vacuum cooler and plate heat exchanger was designed and tested in a real spa resort for six months. Both selected technologies have demonstrated the ability to cool thermal mineral water in long-term operation, as well as the possibility to utilize waste heat for domestic hot water heating. However, fouling problems occur in the plate heat exchanger. The vacuum cooler demonstrated greater operational robustness and resistance to encrustation.
Reducing energy costs in Europe is more challenging than before due to extreme price increases. The use of local renewable energy sources is one way to contribute to this effort. In the case of spa resorts, the use of heat from hot springs for therapeutic baths is an option. It is necessary to cool down this thermal mineral water to a temperature acceptable to the human body. However, due to the high mineral content of this water, heavy fouling can be a problem for conventional heat exchangers. The purpose of this study is to identify the suitable cooling technology in terms of required cooling capacity and waste heat recovery capability. The cooling technology was selected on the basis of a literature search. A pilot cooling unit consisting of vacuum cooler and plate heat exchanger was designed and tested in a real spa resort for six months. Both selected technologies have demonstrated the ability to cool thermal mineral water in long-term operation, as well as the possibility to utilize waste heat for domestic hot water heating. However, fouling problems occur in the plate heat exchanger. The vacuum cooler demonstrated greater operational robustness and resistance to encrustation.

Description

Citation

Energies. 2023, vol. 16, issue 7, 23 p.
https://www.mdpi.com/1996-1073/16/7/2941

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International