Potential Worst-case System for Testing EMI Filters Tested on Simple Filter Models

Loading...
Thumbnail Image

Authors

Drinovsky, Jiri
Svacina, Jiri
Raida, Zbynek

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Společnost pro radioelektronické inženýrství

ORCID

Abstract

This paper deals with the approximate worst-case test method for testing the insertion loss of the EMI filters. The systems with 0.1 Ω and 100 Ω impedances are usually used for this testing. These systems are required by the international CISPR 17 standard. The main disadvantage of this system is the use of two impedance transformers. Especially the impedance transformer with 0.1 Ω output impedance is not easy to be produced. These transformers have usually narrow bandwidth. This paper discusses the alternative system with 1 Ω and 100 Ω impedances. The performance of these systems was tested on several filters’ models and the obtained data are depicted, too. The performance comparison of several filters in several systems is also included. The performance of alternate worst-case system is discussed in the conclusion.

Description

Citation

Radioengineering. 2008, vol. 17, č. 3, s. 15-18. ISSN 1210-2512
http://www.radioeng.cz/fulltexts/2008/08_03_015_018.pdf

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

DOI

Collections

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 3.0 Unported License
Citace PRO