Influence of the gripping fixture on the modified compact tension test results: evaluation of the experiments on cylindrical concrete specimens
dc.contributor.author | Holušová, Táňa | cs |
dc.contributor.author | Lozano, Miguel | cs |
dc.contributor.author | Fernández-Canteli, Alfonso | cs |
dc.contributor.author | Komárková, Tereza | cs |
dc.contributor.author | Kocáb, Dalibor | cs |
dc.contributor.author | Seitl, Stanislav | cs |
dc.coverage.issue | 2 | cs |
dc.coverage.volume | 15 | cs |
dc.date.accessioned | 2018-08-20T10:48:41Z | |
dc.date.available | 2018-08-20T10:48:41Z | |
dc.date.issued | 2015-12-18 | cs |
dc.description.abstract | The modified compact tension test (MCT) might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement) measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced. | en |
dc.description.abstract | The modified compact tension test (MCT) might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement) measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced. | cs |
dc.format | text | cs |
dc.format.extent | 1-11 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series. 2015, vol. 15, issue 2, p. 1-11. | en |
dc.identifier.doi | 10.1515/tvsb-2015-0010 | cs |
dc.identifier.issn | 1804-4824 | cs |
dc.identifier.other | 120515 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/84120 | |
dc.language.iso | en | cs |
dc.publisher | VŠB-TUO | cs |
dc.relation.ispartof | Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series | cs |
dc.relation.uri | http://www.degruyter.com/view/j/tvsb.2015.15.issue-2/tvsb-2015-0010/tvsb-2015-0010.xml?format=INT | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 Unported | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1804-4824/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ | cs |
dc.subject | Modified Compact Tension Test | en |
dc.subject | Fracture Parameters | en |
dc.subject | Cementitious Composites | en |
dc.subject | ARAMIS measurement | en |
dc.subject | grips | en |
dc.subject | Modifikovaná zkouška excentrickým tahem | |
dc.subject | Lomové parametry | |
dc.subject | Cementové kompozity | |
dc.subject | ARAMIS měření | |
dc.subject | úchyty | |
dc.title | Influence of the gripping fixture on the modified compact tension test results: evaluation of the experiments on cylindrical concrete specimens | en |
dc.title.alternative | Vliv uchycení na výsledky modifikované zkoušky excentrickým tahem: vyhodnocení experimentů na válcových betonových tělesech | cs |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-120515 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2020.04.01 11:00:50 | en |
sync.item.modts | 2020.04.01 05:53:08 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Fakulta stavební | cs |
thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Ústav stavebního zkušebnictví | cs |
thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Ústav stavební mechaniky | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 06_Holusova et al. VSB.pdf
- Size:
- 980.1 KB
- Format:
- Adobe Portable Document Format
- Description:
- 06_Holusova et al. VSB.pdf