Seven State PTP for Vector Network Analyzer
Loading...
Date
2005-12
Authors
Zavodny, Vadim
Hoffmann, Karel
Skvor, Zbynek
ORCID
Advisor
Referee
Mark
Journal Title
Journal ISSN
Volume Title
Publisher
Společnost pro radioelektronické inženýrství
Abstract
A new, seven-state switched perturbation two-port (PTP) for vector reflection measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octaves. Good agreement with data obtained using a precise vector network analyzer was achieved. The new calibration method for the PTP was designed and tested on real measured data.
Description
Citation
Radioengineering. 2005, vol. 14, č. 4, s. 87-90. ISSN 1210-2512
http://www.radioeng.cz/fulltexts/2005/05_04_087_090.pdf
http://www.radioeng.cz/fulltexts/2005/05_04_087_090.pdf
Document type
Peer-reviewed
Document version
Published version
Date of access to the full text
Language of document
en