Transient Effects at Power-Supply System of the Czech Railways from EMC Viewpoint
dc.contributor.author | Dolecek, Radovan | |
dc.contributor.author | Hlava, Karel | |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 16 | cs |
dc.date.accessioned | 2016-03-24T06:42:48Z | |
dc.date.available | 2016-03-24T06:42:48Z | |
dc.date.issued | 2007-04 | cs |
dc.description.abstract | The paper deals with the behavior of the traction power-supply system 25 kV, 50 Hz at the Czech Railways. Electrical conditions on a contact line affect electrical conditions in a feeding station. This relation represents galvanic coupling from EMC viewpoint. Explanation of transient effects during short-circuits at the contact line can be considered as the main problem. These effects can arise during a failure in a traction circuit. Therefore, the attention is turned to an adjustment protection design of the traction circuit. Simulation diagrams were created. The design can be utilizable for a feeding station with Filter-Compensation Equipment, which is designed for the EMI reduction. | en |
dc.format | text | cs |
dc.format.extent | 40-44 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2007, vol. 16, č. 1, s. 40-44. ISSN 1210-2512 | cs |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/57275 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | http://www.radioeng.cz/fulltexts/2007/07_01_40_44.pdf | cs |
dc.rights | Creative Commons Attribution 3.0 Unported License | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.subject | Power-supply system | en |
dc.subject | power supply line | en |
dc.subject | Filter-Compensation Equipment | en |
dc.subject | feeding station | en |
dc.subject | contact line | en |
dc.subject | transient effect | en |
dc.subject | harmonic branch | en |
dc.subject | short-circuit | en |
dc.title | Transient Effects at Power-Supply System of the Czech Railways from EMC Viewpoint | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 07_01_40_44.pdf
- Size:
- 271.59 KB
- Format:
- Adobe Portable Document Format
- Description: