Photovoltaic Power Plant Inspection and Diagnostic

dc.contributor.authorVrána, Michalcs
dc.contributor.authorMorávek, Jancs
dc.contributor.authorMastný, Petrcs
dc.coverage.issue3cs
dc.coverage.volume5cs
dc.date.issued2015-09-02cs
dc.description.abstractThis paper presents methods of photovoltaic panel inspection in the field. The aim is to verify value of on-site tests. The basic parameters for comparing the quality of photovoltaic panels are indicated by the manufacturer’s datasheet. Diagnostic in the field commonly uses a combination of different analyzers and infrared cameras. The paper compares the evaluation of the parameters at different climatic conditions by special photovoltaic analyzer, conventional analyzer with recalculation according the IEC standards and flash tester. The comparison of different methods and analyzers has been performed with the practical experience from the measurementsen
dc.description.abstractČlánek popisuje metodiku prohlídky fotovoltaických elektráren s cílem ověřit parametry elektrárny v terénu. Základní parametry jednotlivých komponent jsou udány výrobcem. Diagnostika je provedena s pomocí různých typů analýzátorů a infrakamery. Článek porovnáná jednotlivé analýzátory z hlediska vhodnosti pro použití v terénu a jejich přesnosti, přičemž je provedeno srování přesnosti jednotlivých zařízení.cs
dc.formattextcs
dc.format.extent55-58cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska. 2015, vol. 5, issue 3, p. 55-58.en
dc.identifier.doi10.5604/20830157.1166555cs
dc.identifier.issn2083-0157cs
dc.identifier.orcid0000-0002-1399-8717cs
dc.identifier.orcid0000-0002-8662-7001cs
dc.identifier.orcid0000-0002-4959-2444cs
dc.identifier.other115058cs
dc.identifier.researcheridK-8731-2018cs
dc.identifier.researcheridD-6001-2018cs
dc.identifier.researcheridJ-6568-2013cs
dc.identifier.scopus56267073700cs
dc.identifier.scopus24450825700cs
dc.identifier.urihttp://hdl.handle.net/11012/201063
dc.language.isoencs
dc.publisherLublin University of Technology Publishing Housecs
dc.relation.ispartofInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiskacs
dc.relation.urihttps://ph.pollub.pl/index.php/iapgos/article/view/1067cs
dc.rightsCreative Commons Attribution-ShareAlike 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2083-0157/cs
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/cs
dc.subjectphotovoltaicen
dc.subjectinspectionen
dc.subjectdiagnosticen
dc.subjectperformance testen
dc.subjectflash testen
dc.subjectfotovoltaika
dc.subjectprohlídka
dc.subjectdiagnostika
dc.subjecttest výkonnosti
dc.subjectflash test
dc.titlePhotovoltaic Power Plant Inspection and Diagnosticen
dc.title.alternativeProhlídka a diagnostika fotovoltaických elektrárencs
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-115058en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:40:10en
sync.item.modts2025.01.17 19:34:26en
thesis.grantorVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav elektroenergetikycs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1067Article Text292511020191228.pdf
Size:
409.79 KB
Format:
Adobe Portable Document Format
Description:
1067Article Text292511020191228.pdf