Ultrasonic Approach to Nonivasive Temperature Monitoring During Microwave Thermotherapy
dc.contributor.author | Novak, P. | |
dc.contributor.author | Zuna, I. | |
dc.contributor.author | Pousek, L. | |
dc.contributor.author | Vrba, J. | |
dc.coverage.issue | 2 | cs |
dc.coverage.volume | 10 | cs |
dc.date.accessioned | 2016-05-02T12:05:29Z | |
dc.date.available | 2016-05-02T12:05:29Z | |
dc.date.issued | 2001-06 | cs |
dc.description.abstract | Microwave thermotherapy (MT) is an oncological treatment. At present the invasive thermometer probes are clinically used for temperature measuring during an MT. Any invasive handling of tumors is of high-risk. A new possible method of noninvasive monitoring of temperature distribution in tissue has been developed. An MT treatment of the experimentally induced pedicle-tumors of the rat was prepared. For 100 rat samples a strong correlation between the mean gray level in the ROIs in the ultrasound pictures and the invasively measured temperature in the range 37-44 °C was found. The correlation coefficient of the mean gray level and the invasively measured temperature is 0.96a0.05. A system for representation of changes of spatial temperature distribution of the whole tumor during MT is presented. | en |
dc.format | text | cs |
dc.format.extent | 32-37 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2001, vol. 10, č. 2, s. 32-37. ISSN 1210-2512 | cs |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/58189 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | http://www.radioeng.cz/fulltexts/2001/01_02_32_37.pdf | cs |
dc.rights | Creative Commons Attribution 3.0 Unported License | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.subject | noninvasive temperature measurement | en |
dc.subject | ultrasound | en |
dc.subject | texture analysis | en |
dc.subject | hyperthermia | en |
dc.subject | oncological treat-ment | en |
dc.subject | 3D temperature monitoring | en |
dc.title | Ultrasonic Approach to Nonivasive Temperature Monitoring During Microwave Thermotherapy | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |