Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide

Loading...
Thumbnail Image

Authors

Koudelková, Zuzana
Syrový, Tomáš
Ambrožová, Pavlína
Moravec, Zdeněk
Kubáč, Lubomír
Hynek, David
Richtera, Lukáš
Adam, Vojtěch

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI
Altmetrics

Abstract

In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 mu g center dot L-1 for Zn(II), 3 and 10 mu g center dot L-1 for Cd(II), 3 and 10 mu g center dot L-1 for Pb(II), 3 and 10 mu g center dot L-1 for Cu(II), and 3 and 10 mu g center dot L-1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 mu g center dot L-1 for Zn(II), 25 mu g center dot L-1 for Cd(II), 3 mu g center dot L-1 for Pb(II) and 3 mu g center dot L-1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.
In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 mu g center dot L-1 for Zn(II), 3 and 10 mu g center dot L-1 for Cd(II), 3 and 10 mu g center dot L-1 for Pb(II), 3 and 10 mu g center dot L-1 for Cu(II), and 3 and 10 mu g center dot L-1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 mu g center dot L-1 for Zn(II), 25 mu g center dot L-1 for Cd(II), 3 mu g center dot L-1 for Pb(II) and 3 mu g center dot L-1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.

Description

Citation

SENSORS. 2017, vol. 17, issue 8, p. 1832-1-1832-14.
https://www.mdpi.com/1424-8220/17/8/1832

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO