Pressure and humidity detector based on textile integrated waveguide

Loading...
Thumbnail Image

Authors

Kokolia, Martin
Raida, Zbyněk

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Sciendo
Altmetrics

Abstract

In the paper, a pressure sensor and a humidity sensor are designed as supplementary components of a textile integrated waveguide (TIW) based on an artificial magnetic conductor (AMC) consisting of hexagonal elements. Thanks to AMC, sewing of electrically conductive side walls can be eliminated. Since operating in the stop-band of TIW, the sensors do not influence transmission parameters of TIW, and provide an additional functionality. For fabrication, a three-dimensional knitted fabric was used as a substrate and conductive surfaces were created from a self-adhesive copper foil. The sensors were simulated, manufactured and measured in the frequency range from 10 GHz to 12 GHz with a reasonable agreement. Since the designed components are sensitive on manufacturing tolerances, a higher measured insertion loss in TIW can be observed compared to simulations. Nevertheless, the insertion loss can be reduced when manufacturing accuracy is improved.
In the paper, a pressure sensor and a humidity sensor are designed as supplementary components of a textile integrated waveguide (TIW) based on an artificial magnetic conductor (AMC) consisting of hexagonal elements. Thanks to AMC, sewing of electrically conductive side walls can be eliminated. Since operating in the stop-band of TIW, the sensors do not influence transmission parameters of TIW, and provide an additional functionality. For fabrication, a three-dimensional knitted fabric was used as a substrate and conductive surfaces were created from a self-adhesive copper foil. The sensors were simulated, manufactured and measured in the frequency range from 10 GHz to 12 GHz with a reasonable agreement. Since the designed components are sensitive on manufacturing tolerances, a higher measured insertion loss in TIW can be observed compared to simulations. Nevertheless, the insertion loss can be reduced when manufacturing accuracy is improved.

Description

Citation

Journal of Electrical Engineering-Elektrotechnicky Casopis. 2022, vol. 73, issue 1, p. 57-61.
https://www.sciendo.com/article/10.2478/jee-2022-0008

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 Unported
Citace PRO