Analyzing the Resonance Resultant from the Capacitive Effects in Bulk Current Injection Probe
dc.contributor.author | Mashriki, Issa Moustafa | |
dc.contributor.author | Razavi, Seyyed Mohamad Javad | |
dc.contributor.author | Mohseni Amaki, Seyyed Hossein | |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 29 | cs |
dc.date.accessioned | 2020-05-04T09:39:03Z | |
dc.date.available | 2020-05-04T09:39:03Z | |
dc.date.issued | 2020-04 | cs |
dc.description.abstract | In this paper, the effect of the slot distance, existed between the two parts of BCI-probe shield, on its performance is studied, therefore, two ferrite materials with the same size and different characteristics are used to implement two identical BCI-probes. The input impedance and reflection coefficient are measured for four different values of slot distance 0.5, 1, 2 and 3 mm. Practical results show a notable effect of the slot distance on measured quantities. Measured impedance analysis shows the appearance of three capacitive regions in its spectra, therefore, a three dimensional electromagnetic (EM) model is implemented in CST-Microwave Studio (MWS) software to disclose the main source parameters responsible for it. Results of achieved study, using developed EM model, were in accordance with measured data for the implemented prototypes, and showed the same resonance phenomena. | en |
dc.format | text | cs |
dc.format.extent | 109-116 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2020 vol. 29, č. 1, s. 109-116. ISSN 1210-2512 | cs |
dc.identifier.doi | 10.13164/re.2020.0109 | en |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/186940 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | https://www.radioeng.cz/fulltexts/2019/20_01_0109_0116.pdf | cs |
dc.rights | Creative Commons Attribution 4.0 International license | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | en |
dc.subject | Bulk current injection (BCI) probe | en |
dc.subject | electromagnetic compatibility (EMC) | en |
dc.subject | shield effect | en |
dc.subject | slot capacitance | en |
dc.subject | dielectric constant of ferrite | en |
dc.title | Analyzing the Resonance Resultant from the Capacitive Effects in Bulk Current Injection Probe | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 20_01_0109_0116.pdf
- Size:
- 1.4 MB
- Format:
- Adobe Portable Document Format
- Description: