Airborne FDA-MIMO Radar Modeling and Detection Performance Analysis
dc.contributor.author | Yan, Yisheng | |
dc.contributor.author | Wang, Wen-Qin | |
dc.contributor.author | Basit, Abdul | |
dc.contributor.author | Cai, Jingye | |
dc.coverage.issue | 2 | cs |
dc.coverage.volume | 30 | cs |
dc.date.accessioned | 2021-07-12T08:14:54Z | |
dc.date.available | 2021-07-12T08:14:54Z | |
dc.date.issued | 2021-06 | cs |
dc.description.abstract | In the conventional frequency diverse array (FDA) radar designs, generalized likelihood ratio test (GLRT) detection utilizes coherent pulses. However, the impacts of an FDA multiple-input multiple-output (FDA-MIMO) radar system for detection with incoherent pulses have not been systematically investigated. In this paper, we present an incoherent square-law detector to analyse the performance of both the coherent and non-coherent airborne FDA-MIMO radars in a Neyman-Pearson sense. Moreover, the closed-form expressions of an incoherent square-law detector for the FDA-MIMO radars are derived. For a coherent FDA-MIMO radar, the optimal performance is achieved at a high signal-to-noise ratio (SNR), whereas the superiority of a non-coherent FDA-MIMO radar in distinguishing range dependent targets is validated. The corresponding theoretical derivations are verified by the extensive numerical results to show an improved performance. | en |
dc.format | text | cs |
dc.format.extent | 396-406 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2021 vol. 30, č. 2, s. 396-406. ISSN 1210-2512 | cs |
dc.identifier.doi | 10.13164/re.2021.0396 | en |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/200454 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | https://www.radioeng.cz/fulltexts/2021/21_02_0396_0406.pdf | cs |
dc.rights | Creative Commons Attribution 4.0 International license | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | en |
dc.subject | Coherent and non-coherent FDA-MIMO radar | en |
dc.subject | airborne radar | en |
dc.subject | square-law detector | en |
dc.subject | incoherent pulses | en |
dc.subject | Neyman-Pearson sense | en |
dc.subject | detection performance | en |
dc.subject | range dependent targets | en |
dc.title | Airborne FDA-MIMO Radar Modeling and Detection Performance Analysis | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 21_02_0396_0406.pdf
- Size:
- 639.01 KB
- Format:
- Adobe Portable Document Format
- Description: