Towards the Understanding of Lubrication Mechanisms in Total Knee Replacements – Part I: Experimental Investigations
dc.contributor.author | Nečas, David | cs |
dc.contributor.author | Vrbka, Martin | cs |
dc.contributor.author | Marian, Max | cs |
dc.contributor.author | Rothammer, Benedict | cs |
dc.contributor.author | Tremmel, Stephan | cs |
dc.contributor.author | Wartzack, Sandro | cs |
dc.contributor.author | Galandáková, Adéla | cs |
dc.contributor.author | Gallo, Jiří | cs |
dc.contributor.author | Wimmer, Markus A. | cs |
dc.contributor.author | Křupka, Ivan | cs |
dc.contributor.author | Hartl, Martin | cs |
dc.coverage.issue | 4 | cs |
dc.coverage.volume | 156 | cs |
dc.date.accessioned | 2023-10-02T06:53:21Z | |
dc.date.available | 2023-10-02T06:53:21Z | |
dc.date.issued | 2021-04-01 | cs |
dc.description.abstract | This contribution is aimed at the detailed understanding of lubrication mechanisms within total knee replacement. While Part I is focused on the experimental investigation, Part II deals with the development of a predictive numerical model. Here, a knee simulator was used for direct optical observation of the contacts between a metal femoral and a transparent polymer components. Transient dynamic conditions were applied. Mimicked synovial fluids with fluorescently labelled constituents were used as the test lubricants. The results showed that -globulin forms thin boundary lubricating film, being reinforced by the interaction of phospholipids and hyaluronic acid. Further development of lubricating film is attributed to albumin layering. Based on the results, a novel lubrication model of the knee implant is proposed. | en |
dc.description.abstract | Tato studie je zaměřena na detailní porozumění mechanismů mazání v náhradě kolenního kloubu. Zatímco část I představuje experimentální pozorování, část II se zabývá vývojem prediktivního numerického modelu. V této části studie byl využit kolenní simulátor pro přímé optické pozorování kontaktu kovové femorální komponenty a vložky zhotovené z průhledného polymeru. Byly aplikovány proměnné dynamické podmínky. Jako mazivo byly využity modelové synoviální kapaliny s fluorescenčně označenými složkami. Výsledky ukázaly, že -globulin má tendenci formovat tenkou meznou vrstvu, která je vyztužená fosfolipidy v interakci s kyselinou hyaluronovou. Další nárůst mazacího filmu je připisován vrstvení albuminu. Na základě výsledků je představen nový teoretický model mazací vrstvy v kolenní náhradě. | cs |
dc.format | text | cs |
dc.format.extent | 106874-106874 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | Tribology International. 2021, vol. 156, issue 4, p. 106874-106874. | en |
dc.identifier.doi | 10.1016/j.triboint.2021.106874 | cs |
dc.identifier.issn | 0301-679X | cs |
dc.identifier.orcid | 0000-0002-3843-8732 | cs |
dc.identifier.orcid | 0000-0002-2845-3752 | cs |
dc.identifier.orcid | 0000-0002-9936-7480 | cs |
dc.identifier.orcid | 0000-0001-5432-6645 | cs |
dc.identifier.other | 167649 | cs |
dc.identifier.researcherid | I-7816-2014 | cs |
dc.identifier.researcherid | F-5568-2012 | cs |
dc.identifier.researcherid | D-8147-2012 | cs |
dc.identifier.researcherid | D-8261-2012 | cs |
dc.identifier.scopus | 56635672600 | cs |
dc.identifier.scopus | 7005196946 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/202991 | |
dc.language.iso | en | cs |
dc.publisher | Elsevier | cs |
dc.relation.ispartof | Tribology International | cs |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0301679X21000220 | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/0301-679X/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
dc.subject | Totální náhrada kolene | |
dc.subject | Kolenní simulátor | |
dc.subject | Fluorescenční mikroskopie | |
dc.subject | Mazání | |
dc.subject | Experiment | |
dc.subject | Total knee replacement | en |
dc.subject | Knee simulator | en |
dc.subject | Fluorescent microscopy | en |
dc.subject | Lubrication | en |
dc.subject | Experiment | en |
dc.title | Towards the Understanding of Lubrication Mechanisms in Total Knee Replacements – Part I: Experimental Investigations | en |
dc.title.alternative | Objasnění mechanismů mazání v náhradě kolenního kloubu – Část I: Experimentální studium | cs |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | acceptedVersion | en |
sync.item.dbid | VAV-167649 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2023.10.02 08:53:21 | en |
sync.item.modts | 2023.10.02 08:14:39 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta strojního inženýrství. Ústav konstruování | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 106874_accepted.pdf
- Size:
- 2.94 MB
- Format:
- Adobe Portable Document Format
- Description:
- 106874_accepted.pdf