Comparison of the Accuracy of Data Collection Using Ground Photogrammetry and Laser Scanning with the Subsequent Creation of a 3D Model of the Water Management Object
but.event.date | 25.01.2024 | cs |
but.event.title | Juniorstav 2024 | cs |
dc.contributor.author | Kačerovský, Jonáš | |
dc.date.accessioned | 2024-05-07T08:53:16Z | |
dc.date.available | 2024-05-07T08:53:16Z | |
dc.date.issued | 2024-05-07 | cs |
dc.description.abstract | This article deals with the comparison of data collection using ground photogrammetry and laser scanning. Sample standard deviations were calculated and subsequently compared to evaluate the accuracy of both methods. Points focused using the Leica MS60 Multi-station were selected as the correct values. The ideal data collection method for a structured object was determined after comparing the individual methods. In the next step, a 3D model with BIM parameters of the targeted water management facility was created from data collected using ground photogrammetry. The modelling process took place in the REVIT program, where flexibility was tested on such a specific object. | en |
dc.format | text | cs |
dc.format.extent | 1-9 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Juniorstav 2024: Proceedings 26th International Scientific Conference Of Civil Engineering, s. 1-9. ISBN 978-80-86433-83-7. | cs |
dc.identifier.doi | 10.13164/juniorstav.2024.24036 | en |
dc.identifier.isbn | 978-80-86433-83-7 | |
dc.identifier.uri | https://hdl.handle.net/11012/245371 | |
dc.language.iso | en | cs |
dc.publisher | Vysoké učení technické v Brně,Fakulta stavební | cs |
dc.relation.ispartof | Juniorstav 2024: Proceedings 26th International Scientific Conference Of Civil Engineering | cs |
dc.relation.uri | https://juniorstav.fce.vutbr.cz/proceedings2024/ | |
dc.rights | © Vysoké učení technické v Brně,Fakulta stavební | cs |
dc.rights.access | openAccess | en |
dc.subject | Ground photogrammetry | en |
dc.subject | laser scanning | en |
dc.subject | polar method | en |
dc.subject | BIM | en |
dc.subject | 3D models | en |
dc.subject | digital twin | en |
dc.title | Comparison of the Accuracy of Data Collection Using Ground Photogrammetry and Laser Scanning with the Subsequent Creation of a 3D Model of the Water Management Object | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.department | Fakulta stavební | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- juniorstav-2024-24036.pdf
- Size:
- 562.58 KB
- Format:
- Adobe Portable Document Format
- Description: