Design Of The Shape Of The Experimental Chamber For The Analysis Of The Pressure Layout In The Differential Pumped Chamber
but.event.date | 26.04.2018 | cs |
but.event.title | Student EEICT 2018 | cs |
dc.contributor.author | Hájková, Věra | |
dc.date.accessioned | 2019-03-04T10:05:32Z | |
dc.date.available | 2019-03-04T10:05:32Z | |
dc.date.issued | 2018 | cs |
dc.description.abstract | This article is based on a study of Dr. Danilatos, where pumping of the differential pumped chamber is solved using the Monte Carlo statistical method. Similar results were obtained using the Ansys Fluent system. Theoretical computations as Dr. Danilatos and comparative studies are performed on theoretical shape. Simulations were made to obtain the shape of an experimental chamber with complete pumping shapes so that its shaping and pumping would ensure such a flow of gas to ensure the same distribution of pressure in the experimental chamber in the area under investigation as in the theoretical shape. | en |
dc.format | text | cs |
dc.format.extent | 5-8 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Proceedings of the 24th Conference STUDENT EEICT 2018. s. 5-8. ISBN 978-80-214-5614-3 | cs |
dc.identifier.isbn | 978-80-214-5614-3 | |
dc.identifier.uri | http://hdl.handle.net/11012/138151 | |
dc.language.iso | en | cs |
dc.publisher | Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.relation.ispartof | Proceedings of the 24th Conference STUDENT EEICT 2018 | en |
dc.relation.uri | http://www.feec.vutbr.cz/EEICT/ | cs |
dc.rights | © Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.rights.access | openAccess | en |
dc.subject | Shockwave | en |
dc.subject | ANSYS Fluent | en |
dc.subject | ANSYS Mechanics | en |
dc.subject | Optical methods | en |
dc.subject | Pitot tube | en |
dc.subject | Pressure measurement | en |
dc.subject | Solidworks | en |
dc.subject | Thermography | en |
dc.title | Design Of The Shape Of The Experimental Chamber For The Analysis Of The Pressure Layout In The Differential Pumped Chamber | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.department | Fakulta elektrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- eeict2018-5.pdf
- Size:
- 720.56 KB
- Format:
- Adobe Portable Document Format
- Description: