A Microwave Metamaterial Inspired Sensor for Non-Invasive Blood Glucose Monitoring
dc.contributor.author | Vrba, Jan | |
dc.contributor.author | Vrba, David | |
dc.coverage.issue | 4 | cs |
dc.coverage.volume | 24 | cs |
dc.date.accessioned | 2016-01-06T08:08:07Z | |
dc.date.available | 2016-01-06T08:08:07Z | |
dc.date.issued | 2015-12 | cs |
dc.description.abstract | In this paper, a microwave sensor based on an artificial transmission line is proposed for non-invasive blood glucose monitoring. A corresponding numerical model of the sensor implemented in microstrip technology is created in the commercial full-wave numerical simulation tool COMSOL Multiphysics and virtually tested by means of numerical simulations. Blood-glucose solution models with various blood glucose concentrations are used as a model of a biological tissue under test. Furthermore, a possible methodology for performing non-invasive tests is proposed. Sensitivity of the sensor developed here is compared to a sensor based on a section of a conventional microstrip transmission line of the same length and width. | en |
dc.format | text | cs |
dc.format.extent | 877-884 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2015 vol. 24, č. 4, s. 877-884. ISSN 1210-2512 | cs |
dc.identifier.doi | 10.13164/re.2015.0877 | en |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/51884 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | http://www.radioeng.cz/fulltexts/2015/15_04_0877_0884.pdf | cs |
dc.rights | Creative Commons Attribution 3.0 Unported License | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.subject | Artificial transmission line | en |
dc.subject | metamaterial | en |
dc.subject | microwave | en |
dc.subject | sensor | en |
dc.subject | blood glucose | en |
dc.subject | concentration | en |
dc.subject | non-invasive | en |
dc.title | A Microwave Metamaterial Inspired Sensor for Non-Invasive Blood Glucose Monitoring | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |