Electromagnetic compatibility of PLC adapters for in-home/domestic networks

dc.contributor.authorOrgoň, Milošcs
dc.contributor.authorFujdiak, Radekcs
dc.coverage.issue1cs
dc.coverage.volume69cs
dc.date.issued2018-02-19cs
dc.description.abstractThe use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems.en
dc.formattextcs
dc.format.extent79-84cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationJournal of Electrical Engineering . 2018, vol. 69, issue 1, p. 79-84.en
dc.identifier.doi10.1515/jee-2018-0011cs
dc.identifier.issn1335-3632cs
dc.identifier.orcid0000-0002-8319-0633cs
dc.identifier.other145844cs
dc.identifier.scopus56610269000cs
dc.identifier.urihttp://hdl.handle.net/11012/70906
dc.language.isoencs
dc.publisherFaculty of Electrical Engineering and Information Technology of the Slovak University of Technologycs
dc.relation.ispartofJournal of Electrical Engineeringcs
dc.relation.urihttp://iris.elf.stuba.sk/JEEEC/data/pdf/1_118-11.pdfcs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 3.0 Unportedcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1335-3632/cs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cs
dc.subjectPLCen
dc.subjecthome appliancesen
dc.subjectdomestic newtworksen
dc.titleElectromagnetic compatibility of PLC adapters for in-home/domestic networksen
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-145844en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:42:44en
sync.item.modts2025.01.17 15:24:48en
thesis.grantorVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikacícs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1_11811.pdf
Size:
205.77 KB
Format:
Adobe Portable Document Format
Description:
1_11811.pdf