Direct coupling of a free-flow isotachophoresis (FFITP) device with electrospray ionization mass spectrometry (ESI-MS)
| dc.contributor.author | Park, J.K. | cs |
| dc.contributor.author | Madeira Campos, Camila D. | cs |
| dc.contributor.author | Neužil, Pavel | cs |
| dc.contributor.author | Abelmann, Leon | cs |
| dc.contributor.author | Guijt, Rosanne Marieke | cs |
| dc.coverage.issue | 15 | cs |
| dc.coverage.volume | 15 | cs |
| dc.date.issued | 2015-07-09 | cs |
| dc.description.abstract | The direct coupling of free-flow isotachophoresis device with an electrospray-ionization-mass-spectrometer allows continuous online detection without any sample preparation such as purification and labeling. | en |
| dc.description.abstract | The direct coupling of free-flow isotachophoresis device with an electrospray-ionization-mass-spectrometer allows continuous online detection without any sample preparation such as purification and labeling. | en |
| dc.format | text | cs |
| dc.format.extent | 3495-3502 | cs |
| dc.format.mimetype | application/pdf | cs |
| dc.identifier.citation | Lab on a chip. 2015, vol. 15, issue 15, p. 3495-3502. | en |
| dc.identifier.doi | 10.1039/c5lc00523j | cs |
| dc.identifier.issn | 1473-0197 | cs |
| dc.identifier.other | 115301 | cs |
| dc.identifier.uri | http://hdl.handle.net/11012/61772 | |
| dc.language.iso | en | cs |
| dc.publisher | Royal Society of Chemistry | cs |
| dc.relation.ispartof | Lab on a chip | cs |
| dc.relation.uri | http://pubs.rsc.org/en/content/articlelanding/2015/lc/c5lc00523j#!divAbstract | cs |
| dc.rights | Creative Commons Attribution 3.0 Unported | cs |
| dc.rights.access | openAccess | cs |
| dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1473-0197/ | cs |
| dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | cs |
| dc.subject | free-flow | en |
| dc.subject | isotachophoresis | en |
| dc.subject | electrospray | en |
| dc.subject | mass spectrometry | en |
| dc.subject | free-flow | |
| dc.subject | isotachophoresis | |
| dc.subject | electrospray | |
| dc.subject | mass spectrometry | |
| dc.title | Direct coupling of a free-flow isotachophoresis (FFITP) device with electrospray ionization mass spectrometry (ESI-MS) | en |
| dc.title.alternative | Direct coupling of a free-flow isotachophoresis (FFITP) device with electrospray ionization mass spectrometry (ESI-MS) | en |
| dc.type.driver | article | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
| sync.item.dbid | VAV-115301 | en |
| sync.item.dbtype | VAV | en |
| sync.item.insts | 2025.10.14 15:17:02 | en |
| sync.item.modts | 2025.10.14 10:50:42 | en |
| thesis.grantor | Vysoké učení technické v Brně. Středoevropský technologický institut VUT. Chytré nanonástroje | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- C5lc00523j_FFIT.pdf
- Size:
- 5.2 MB
- Format:
- Adobe Portable Document Format
- Description:
- C5lc00523j_FFIT.pdf