A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed.
A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed.

Description

Citation

ARSA - Proceedings in ARSA - Advanced Research in Scientific Areas. 2014, vol. 3, p. 331-335.
http://arsa-conf.com/archive/?vid=1&aid=2&kid=60301-72

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

DOI

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution-NonCommercial 4.0 International
Citace PRO