Abstract

Cataract is the most common cause of blindness. The only way to treat it is the cataract surgery during which the affected crystalline lens is destroyed and removed from the eye and replaced with an implantable intraocular lens. After the cataract surgery, a displacement of the intraocular lens from its aligned position happens in some cases. The lenses may be of several designs and their properties are subject to regulatory standards. These standards, however, do not include testing of the postoperative displacement of the lens. For this purpose, an optomechanical eye model setup was previously developed to enable measuring of the wavefront aberrations of the intraocular lenses. As this setup does not perfectly mimic the physiology of the human eye and the manipulation with it may sometimes introduce unwanted errors, the objective of this thesis is to fight the above-mentioned imperfections and develop a new, enhanced eye model setup which will address these.
Cataract is the most common cause of blindness. The only way to treat it is the cataract surgery during which the affected crystalline lens is destroyed and removed from the eye and replaced with an implantable intraocular lens. After the cataract surgery, a displacement of the intraocular lens from its aligned position happens in some cases. The lenses may be of several designs and their properties are subject to regulatory standards. These standards, however, do not include testing of the postoperative displacement of the lens. For this purpose, an optomechanical eye model setup was previously developed to enable measuring of the wavefront aberrations of the intraocular lenses. As this setup does not perfectly mimic the physiology of the human eye and the manipulation with it may sometimes introduce unwanted errors, the objective of this thesis is to fight the above-mentioned imperfections and develop a new, enhanced eye model setup which will address these.

Description

Citation

DVOŘÁK, F. Enhancement of a mechanical eye model setup for IOL testing [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022.

Document type

Document version

Date of access to the full text

Language of document

en

Study field

bez specializace

Comittee

Date of acceptance

2022-11-09

Defence

Student Ferdinand Dvořák úspěšně obhájil svou diplomovou práci a prokázal znalosti v oblasti teorie v rámci odborné rozpravy.

Result of defence

práce byla úspěšně obhájena