Double three-phase PMSM structures for fail operational control

dc.contributor"European Union (EU)" & "Horizon 2020"en
dc.contributor.authorKozovský, Matúšcs
dc.contributor.authorBlaha, Petrcs
dc.coverage.issue27cs
dc.coverage.volume52cs
dc.date.accessioned2020-02-19T11:54:30Z
dc.date.available2020-02-19T11:54:30Z
dc.date.issued2019-10-29cs
dc.description.abstractThis paper deals with permanent magnet synchronous motors (PMSM) structures. Especially their double three-phase arrangements are analysed in detail. Comparison of three different structures is treated. Non-overlapping concentrated winding is the first analysed structure. Distributed winding arrangement with interlaced sub-systems and also distributed winding arrangement with segregated sub-systems follows. The behaviour of all motor structures during normal operation is the same but the properties during faults are different. The motor behaviour during active short circuit (ASC) is discussed. ASC of whole motor and also partial ASC tests were performed. Current waveforms in different operating points are compared. Results show differences of individual structures with respect to operation during fault.en
dc.formattextcs
dc.format.extent1-6cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationIFAC-PapersOnLine (ELSEVIER). 2019, vol. 52, issue 27, p. 1-6.en
dc.identifier.doi10.1016/j.ifacol.2019.12.733cs
dc.identifier.issn2405-8963cs
dc.identifier.other159657cs
dc.identifier.urihttp://hdl.handle.net/11012/184626
dc.language.isoencs
dc.publisherIFACcs
dc.relation.ispartofIFAC-PapersOnLine (ELSEVIER)cs
dc.relation.projectIdinfo:eu-repo/grantAgreement/EC/H2020/737469/EU//AutoDriveen
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S2405896319326825cs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2405-8963/cs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/cs
dc.subjectDouble three-phase motoren
dc.subjectMulti-phase motoren
dc.subjectPMSMen
dc.subjectMotor structureen
dc.titleDouble three-phase PMSM structures for fail operational controlen
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-159657en
sync.item.dbtypeVAVen
sync.item.insts2020.04.16 11:56:31en
sync.item.modts2020.04.16 11:29:42en
thesis.grantorVysoké učení technické v Brně. Středoevropský technologický institut VUT. Kybernetika pro materiálové vědycs
thesis.grantorVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav automatizace a měřicí technikycs