dc.description.abstract | This paper deals with permanent magnet synchronous motors (PMSM) structures. Especially their double three-phase arrangements are analysed in detail. Comparison of three different structures is treated. Non-overlapping concentrated winding is the first analysed structure. Distributed winding arrangement with interlaced sub-systems and also distributed winding arrangement with segregated sub-systems follows. The behaviour of all motor structures during normal operation is the same but the properties during faults are different. The motor behaviour during active short circuit (ASC) is discussed. ASC of whole motor and also partial ASC tests were performed. Current waveforms in different operating points are compared. Results show differences of individual structures with respect to operation during fault. | en |
dc.format | text | cs |
dc.format.extent | 1-6 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | IFAC-PapersOnLine (ELSEVIER). 2019, vol. 52, issue 27, p. 1-6. | en |
dc.identifier.doi | 10.1016/j.ifacol.2019.12.733 | cs |
dc.identifier.issn | 2405-8963 | cs |
dc.identifier.other | 159657 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/184626 | |
dc.language.iso | en | cs |
dc.publisher | IFAC | cs |
dc.relation.ispartof | IFAC-PapersOnLine (ELSEVIER) | cs |
dc.relation.projectId | info:eu-repo/grantAgreement/EC/H2020/737469/EU//AutoDrive | en |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S2405896319326825 | cs |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/2405-8963/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
dc.subject | Double three-phase motor | en |
dc.subject | Multi-phase motor | en |
dc.subject | PMSM | en |
dc.subject | Motor structure | en |
dc.title | Double three-phase PMSM structures for fail operational control | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-159657 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2020.04.16 11:56:31 | en |
sync.item.modts | 2020.04.16 11:29:42 | en |
thesis.grantor | Vysoké učení technické v Brně. Středoevropský technologický institut VUT. Kybernetika pro materiálové vědy | cs |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav automatizace a měřicí techniky | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Double threephase motor structures.pdf
- Size:
- 590.16 KB
- Format:
- Adobe Portable Document Format
- Description:
- Double threephase motor structures.pdf