Abstract

Increasing energy usage efficiency requires enhanced heat energy recuperation between process streams in the industry and civic sector with waste heat utilization. The condensation of different vapours is the process encountered in many industrial applications. Increasing the heat recuperation in this process is possible with efficient heat transfer equipment, among which a Plate Heat Exchanger (PHE) is at the leading position. A number of research works have been conducted in recent years concerning construction development and heat transfer enhancement in conditions of limited pressure drop to increase PHE performance in condensation processes. The results of studies on heat transfer and pressure drop in the two-phase condensing flow inside channels of PHE with different geometries of corrugations are discussed. In many implementations, the total pressure drop allowable for gaseous streams in heat exchangers is relatively small. The structure of two-phase flow in PHE channels of complex geometry is very different than in tubes and flat wall channels. The relative differences in approaches to enhance PHE performance in condensation processes based on its modelling, optimisation and design are analyzed. The directions and prospects for future developments are formulated, and potential savings for the economy and the environmental footprint is presented.
Increasing energy usage efficiency requires enhanced heat energy recuperation between process streams in the industry and civic sector with waste heat utilization. The condensation of different vapours is the process encountered in many industrial applications. Increasing the heat recuperation in this process is possible with efficient heat transfer equipment, among which a Plate Heat Exchanger (PHE) is at the leading position. A number of research works have been conducted in recent years concerning construction development and heat transfer enhancement in conditions of limited pressure drop to increase PHE performance in condensation processes. The results of studies on heat transfer and pressure drop in the two-phase condensing flow inside channels of PHE with different geometries of corrugations are discussed. In many implementations, the total pressure drop allowable for gaseous streams in heat exchangers is relatively small. The structure of two-phase flow in PHE channels of complex geometry is very different than in tubes and flat wall channels. The relative differences in approaches to enhance PHE performance in condensation processes based on its modelling, optimisation and design are analyzed. The directions and prospects for future developments are formulated, and potential savings for the economy and the environmental footprint is presented.

Description

Citation

Energies. 2023, vol. 16, issue 1, p. 1-18.
https://www.mdpi.com/1996-1073/16/1/524

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO