Implementation and verification of the PMSM stator interturn short fault detection algorithm

Loading...
Thumbnail Image

Authors

Otava, Lukáš
Buchta, Luděk

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

IEEE
Altmetrics

Abstract

This paper discusses the stator winding interturn short fault detection for three phase Permanent Magnet Synchronous Machines (PMSMs). The implementation of the Extended Kalman filter (EKF)-based fault detection algorithm is discussed. The implemented algorithm was verified with the emulated fault during different operating conditions of the drive. Measurements on a real PMSM and the implementation verification are the most important objectives of the article.
This paper discusses the stator winding interturn short fault detection for three phase Permanent Magnet Synchronous Machines (PMSMs). The implementation of the Extended Kalman filter (EKF)-based fault detection algorithm is discussed. The implemented algorithm was verified with the emulated fault during different operating conditions of the drive. Measurements on a real PMSM and the implementation verification are the most important objectives of the article.

Description

Citation

19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe) 2017. 2017, p. P.1-P.10.
http://ieeexplore.ieee.org/document/8099080/

Document type

Peer-reviewed

Document version

Accepted version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Citace PRO