Analysis Of Broken Rotor Bars Fault In Inverter Fed Induction Motor By Means Of Motor Current Signature Analysis And Stray Flux Of Motor
but.event.date | 27.04.2017 | cs |
but.event.title | Student EEICT 2017 | cs |
dc.contributor.author | Chernyavska, Ielyzaveta | |
dc.date.accessioned | 2020-05-07T09:40:33Z | |
dc.date.available | 2020-05-07T09:40:33Z | |
dc.date.issued | 2017 | cs |
dc.description.abstract | In this paper the analysis of effect of broken rotor bar fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of investigated fault in case of different types of supply and load. There were measured 4-pole motors with different level of broken rotor bar fault under different loads. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out. | en |
dc.format | text | cs |
dc.format.extent | 593-597 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Proceedings of the 23st Conference STUDENT EEICT 2017. s. 593-597. ISBN 978-80-214-5496-5 | cs |
dc.identifier.isbn | 978-80-214-5496-5 | |
dc.identifier.uri | http://hdl.handle.net/11012/187172 | |
dc.language.iso | en | cs |
dc.publisher | Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.relation.ispartof | Proceedings of the 23st Conference STUDENT EEICT 2017 | en |
dc.relation.uri | http://www.feec.vutbr.cz/EEICT/ | cs |
dc.rights | © Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.rights.access | openAccess | en |
dc.subject | squirrel-cage induction motor fault | en |
dc.subject | motor current signature analysis | en |
dc.subject | stray flux | en |
dc.subject | broken rotor bars | en |
dc.subject | inverter | en |
dc.subject | fault diagnosis | en |
dc.subject | condition monitoring | en |
dc.title | Analysis Of Broken Rotor Bars Fault In Inverter Fed Induction Motor By Means Of Motor Current Signature Analysis And Stray Flux Of Motor | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |