Analysis Of Broken Rotor Bars Fault In Inverter Fed Induction Motor By Means Of Motor Current Signature Analysis And Stray Flux Of Motor

but.event.date27.04.2017cs
but.event.titleStudent EEICT 2017cs
dc.contributor.authorChernyavska, Ielyzaveta
dc.date.accessioned2020-05-07T09:40:33Z
dc.date.available2020-05-07T09:40:33Z
dc.date.issued2017cs
dc.description.abstractIn this paper the analysis of effect of broken rotor bar fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of investigated fault in case of different types of supply and load. There were measured 4-pole motors with different level of broken rotor bar fault under different loads. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.en
dc.formattextcs
dc.format.extent593-597cs
dc.format.mimetypeapplication/pdfen
dc.identifier.citationProceedings of the 23st Conference STUDENT EEICT 2017. s. 593-597. ISBN 978-80-214-5496-5cs
dc.identifier.isbn978-80-214-5496-5
dc.identifier.urihttp://hdl.handle.net/11012/187172
dc.language.isoencs
dc.publisherVysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.relation.ispartofProceedings of the 23st Conference STUDENT EEICT 2017en
dc.relation.urihttp://www.feec.vutbr.cz/EEICT/cs
dc.rights© Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.rights.accessopenAccessen
dc.subjectsquirrel-cage induction motor faulten
dc.subjectmotor current signature analysisen
dc.subjectstray fluxen
dc.subjectbroken rotor barsen
dc.subjectinverteren
dc.subjectfault diagnosisen
dc.subjectcondition monitoringen
dc.titleAnalysis Of Broken Rotor Bars Fault In Inverter Fed Induction Motor By Means Of Motor Current Signature Analysis And Stray Flux Of Motoren
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
eprints.affiliatedInstitution.departmentFakulta elektrotechniky a komunikačních technologiícs