Comparison Of Power Quality Monitor Data Transmission Between Modbus Tcp/Ip And Iec 60870-5-104
but.event.date | 23.04.2020 | cs |
but.event.title | Student EEICT 2020 | cs |
dc.contributor.author | Musil, Petr | |
dc.date.accessioned | 2021-07-15T13:12:40Z | |
dc.date.available | 2021-07-15T13:12:40Z | |
dc.date.issued | 2020 | cs |
dc.description.abstract | With deployment of smart devices along the electrical grid key infrastructure points, communication process with regards to its volume and load on communication infrastructure needs to be described and evaluated. This article focuses on protocol Modbus TCP/IP and standard IEC 60870- 5-104 with regard to their communication structure and principles within substation connected to network by broadband over power lines modems (BPL). This paper also offers two communication scenarios over BPL network by using real substation power quality monitor. Furthermore, performance of each solution is being summed up in the discussion. Conclusion offers a convenient solution for utilization of key values transmission on limited communication channel. | en |
dc.format | text | cs |
dc.format.extent | 234-238 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Proceedings II of the 26st Conference STUDENT EEICT 2020: Selected Papers. s. 234-238. ISBN 978-80-214-5868-0 | cs |
dc.identifier.isbn | 978-80-214-5868-0 | |
dc.identifier.uri | http://hdl.handle.net/11012/200660 | |
dc.language.iso | en | cs |
dc.publisher | Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.relation.ispartof | Proceedings II of the 26st Conference STUDENT EEICT 2020: Selected papers | en |
dc.relation.uri | https://conf.feec.vutbr.cz/eeict/EEICT2020 | cs |
dc.rights | © Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií | cs |
dc.rights.access | openAccess | en |
dc.subject | broadband over power lines | en |
dc.subject | IEC 60870-5-104 | en |
dc.subject | Modbus TCP/IP | en |
dc.subject | Smart Grid | en |
dc.subject | substation | en |
dc.title | Comparison Of Power Quality Monitor Data Transmission Between Modbus Tcp/Ip And Iec 60870-5-104 | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.department | Fakulta elektrotechniky a komunikačních technologií | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 234-eeict_2.pdf
- Size:
- 868.13 KB
- Format:
- Adobe Portable Document Format
- Description: