Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method

dc.contributor.authorApostolopoulos, Vasileioscs
dc.contributor.authorTomáš, Tomášcs
dc.contributor.authorBoháč, Petrcs
dc.contributor.authorMarcián, Petrcs
dc.contributor.authorMahdal, Michalcs
dc.contributor.authorValoušek, Tomášcs
dc.contributor.authorJaníček, Pavelcs
dc.contributor.authorNachtnebl, Lubošcs
dc.coverage.issue1cs
dc.coverage.volume220cs
dc.date.issued2022-04-28cs
dc.description.abstractBackground and objective: Total knee arthroplasty (TKA) with modern all-polyethylene tibial (APT) components has shown high long-term survival rates and comparable results to those with metal-backed tibial components. Nevertheless, APT components are primarily recommended for older and low-demand patients. There are no evidence-based biomechanical guidelines for orthopaedic surgeons to determine the appropriate lower age limit for implantation of APT components. A biomechanical analysis was assumed to be suitable to evaluate the clinical results in patients under 70 years. The scope of this study was to determine biomechanically the appropriate lower age limit for implantation of APT components.& nbsp;Methods: To generate data of the highest possible quality, the geometry of the computational models was created based on computed tomography (CT) images of a representative patient. The cortical bone tissue model distinguishes the change in mechanical properties described in three parts from the tibial cut. The cancellous bone material model has a heterogeneous distribution of mechanical properties. The values used to determine the material properties of the tissues were obtained from measurements of a CT dataset comprising 45 patients.& nbsp;Results: Computational modeling showed that in the majority of the periprosthetic volume, the von Mises strain equivalent ranges from 200 to 2700 its; these strain values induce bone modeling and remodeling. The highest measured deformation value was 2910 its. There was no significant difference in the induced mechanical response between bone models of the 60-year and 70-year age groups, and there was < 3% difference from the 65-year age group.& nbsp;Conclusions: Considering in silico limitations, we suggest that APT components could be conveniently used on a bone with mechanical properties of the examined age categories. Under defined loading conditions, implantation of TKA with APT components is expected to induce modeling and remodeling of the periprosthetic tibia. Following clinical validation, the results of our study could modify the indication criteria of the procedure, and lead to more frequent implantation of all-polyethylene TKA in younger patients. (c) 2022 The Authors. Published by Elsevier B.V.& nbsp;en
dc.formattextcs
dc.format.extent1-9cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationCOMPUTER METHODS AND PROGRAMS IN BIOMEDICINE. 2022, vol. 220, issue 1, p. 1-9.en
dc.identifier.doi10.1016/j.cmpb.2022.106834cs
dc.identifier.issn0169-2607cs
dc.identifier.orcid0009-0006-8718-101Xcs
dc.identifier.orcid0000-0002-9458-9690cs
dc.identifier.other178256cs
dc.identifier.researcheridE-7359-2017cs
dc.identifier.scopus55156647700cs
dc.identifier.urihttp://hdl.handle.net/11012/208144
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofCOMPUTER METHODS AND PROGRAMS IN BIOMEDICINEcs
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S0169260722002164cs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/0169-2607/cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectOrthopaedic biomechanicsen
dc.subjectTotal knee arthroplastyen
dc.subjectBone mechanicsen
dc.subjectAll-polyethylene tibial componenten
dc.subjectFinite element modelen
dc.subjectvon Mises strainen
dc.titleBiomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element methoden
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-178256en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:49:16en
sync.item.modts2025.01.17 18:43:30en
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Ústav mechaniky těles, mechatroniky a biomechanikycs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1s2.0S0169260722002164main.pdf
Size:
2.55 MB
Format:
Adobe Portable Document Format
Description: