Determination accuracy of analysis refractory materials by x-ray fluorescence

dc.contributor.authorJanča, Martincs
dc.contributor.authorŠiler, Pavelcs
dc.contributor.authorOpravil, Tomášcs
dc.contributor.authorKotrla, Jancs
dc.coverage.volume379cs
dc.date.issued2018-07-12cs
dc.description.abstractThis work was focused on the finding of the right way how to analyze refractory materials by X-ray fluorescence. This method can provide accurate results which can be easily repeated, what is the reason why this method is commonly used in industry. Using of the fluorescent spectrometric analysis comes with one issue, which is the presence of many distorting interferences. From this particular reason it is necessary to identify these interferences and then find the ideal solution for their elimination. The choosing of the right method of sample preparation is basic point for making of well analyze results. The differences are shown on the refractory materials samples. All the values were compared according to standards compositions. In this case we compare different conditions of measurement, under air and vacuum. And different preparation form in powder or fusion into pearl.en
dc.formattextcs
dc.format.extent1-7cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationIOP Conference Series: Materials Science and Engineering. 2018, vol. 379, p. 1-7.en
dc.identifier.doi10.1088/1757-899X/379/1/012034cs
dc.identifier.issn1757-899Xcs
dc.identifier.orcid0000-0002-8641-9624cs
dc.identifier.orcid0000-0002-0383-1577cs
dc.identifier.orcid0000-0003-3851-3939cs
dc.identifier.orcid0000-0001-9771-6563cs
dc.identifier.other148518cs
dc.identifier.scopus57203101015cs
dc.identifier.urihttp://hdl.handle.net/11012/84145
dc.language.isoencs
dc.publisherIOP Publishingcs
dc.relation.ispartofIOP Conference Series: Materials Science and Engineeringcs
dc.relation.urihttp://iopscience.iop.org/article/10.1088/1757-899X/379/1/012034cs
dc.rightsCreative Commons Attribution 3.0 Unportedcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1757-899X/cs
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/cs
dc.subjectX-ray fluorescenceen
dc.subjectrefractoryen
dc.subjectfusionen
dc.titleDetermination accuracy of analysis refractory materials by x-ray fluorescenceen
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-148518en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:37:45en
sync.item.modts2025.01.17 18:35:29en
thesis.grantorVysoké učení technické v Brně. Fakulta chemická. CMV - laboratoř anorganických materiálůcs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Janca_2018_IOP_Conf._Ser.__Mater._Sci._Eng._379_012034.pdf
Size:
807.14 KB
Format:
Adobe Portable Document Format
Description:
Janca_2018_IOP_Conf._Ser.__Mater._Sci._Eng._379_012034.pdf