Heat Flow through a Facede with a Controlled Ventilated Gap

Loading...
Thumbnail Image

Authors

Rubina, Aleš
Uher, Pavel
Vrána, Jakub
Novotný, Miloslav
Nespěšný, Ondřej
Skřek, Daniel
Šuhajdová, Eva
Vystrčil, Jan
Formánek, Marian

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI
Altmetrics

Abstract

The article presents current research results in the field of airflow through a façade with a width of 1 m and a height of 13.7 m and with a ventilated gap, and its effect on the year-round heat balance of this façade. An idea to influence airflow in the ventilated gap of the façade is presented based on the results of developed software and the suitability of closing the air gap in winter and in the transition period of the year is described. First, the boundary conditions of the calculations, which are further used in the energy balance between the interior of the building and the exterior environment are defined. In order to include these influences, a discrete analytical calculation was created. It consists of the time distribution of the investigated thermal phenomena calculations. A significant finding is an obvious benefit of controlling the airflow through a ventilated gap in the winter and especially in the transitional period of the year. This technological knowledge has a high potential for energy savings related to the heating of buildings. As the calculations show, airflow control through a ventilated façade reduces heat flow by 25–30% on average, and in contrast, it increases heat gains by 20% and the specific values are presented within the article.
The article presents current research results in the field of airflow through a façade with a width of 1 m and a height of 13.7 m and with a ventilated gap, and its effect on the year-round heat balance of this façade. An idea to influence airflow in the ventilated gap of the façade is presented based on the results of developed software and the suitability of closing the air gap in winter and in the transition period of the year is described. First, the boundary conditions of the calculations, which are further used in the energy balance between the interior of the building and the exterior environment are defined. In order to include these influences, a discrete analytical calculation was created. It consists of the time distribution of the investigated thermal phenomena calculations. A significant finding is an obvious benefit of controlling the airflow through a ventilated gap in the winter and especially in the transitional period of the year. This technological knowledge has a high potential for energy savings related to the heating of buildings. As the calculations show, airflow control through a ventilated façade reduces heat flow by 25–30% on average, and in contrast, it increases heat gains by 20% and the specific values are presented within the article.

Description

Citation

Buildings. 2023, vol. 13, issue 3, p. 1-20.
https://www.mdpi.com/2075-5309/13/3/817

Document type

Peer-reviewed

Document version

Published version

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO