dc.description.abstractThere is presented the fluid flow in the T-junction with the 90 degree angle of the adjacent branch and with the 50mm diameter of each branch, in this chapter. The flow is organized as a combining flow. It means that there are two inlet branches and only one outlet branch. There are two possible kinds of the flow combinations for this T-junction. The CFD calculations and the PIV measurements were done for both flow combinations. Its comparison is presented in this paper.en
dc.description.abstractV této kapitole jsou uvedeny výsledky srovnání výpočtů a PIV měření proudění kapaliny rozvětvením tvaru T. Průměry všech větví jsou 50mm. Jedná se o soutok proudů ze dvou větví. Pro soutok existují dva způsoby uspořádání průtoků. V této kapitole jsou uvedeny výsledky srovnání PIV měření a numerického modelování pro oba typy uspořádání průtoků.cs
dc.formattextcs
dc.format.extent19-27cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationProcedia Engineering. 2011, vol. 39, issue 1, p. 19-27.en
dc.identifier.doi10.1016/j.proeng.2012.07.003cs
dc.identifier.issn1877-7058cs
dc.identifier.orcid0000-0003-2250-6195cs
dc.identifier.orcid0000-0002-2002-542Xcs
dc.identifier.other94241cs
dc.identifier.researcheridH-1970-2018cs
dc.identifier.researcheridY-9531-2019cs
dc.identifier.scopus38362400300cs
dc.identifier.scopus55600110700cs
dc.identifier.urihttp://hdl.handle.net/11012/194732
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofProcedia Engineeringcs
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S1877705812023892cs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 3.0 Unportedcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1877-7058/cs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cs
dc.subjectCombining T-Junctionen
dc.subjectPIV measurementsen
dc.subjectCFD calculationsen
dc.subjectSoutok v rozvětvení
dc.subjectPIV měření
dc.subjectCFD výpočty.
dc.titleThe Fluid Flow in the T-Junction the Comparison of the Numerical Modelling and PIV Measurementen
dc.title.alternativeProudění v rozvětvení. Srovnání numerického modelování a měřením pomocí PIVcs
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-94241en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:46:50en
sync.item.modts2025.01.17 18:39:31en
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Energetický ústavcs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1s2.0S1877705812023892main.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format
Description:
1s2.0S1877705812023892main.pdf