Impact of the Number of Measurements on Result Distortion

but.event.date23.04.2024cs
but.event.titleSTUDENT EEICT 2024cs
dc.contributor.authorKuchařík, Jan
dc.contributor.authorŠimek, Antonín
dc.date.accessioned2024-07-09T07:38:40Z
dc.date.available2024-07-09T07:38:40Z
dc.date.issued2024cs
dc.description.abstractThis study investigates the distortion of results due to the number of corrosion current measurements. Samples were prepared by pressing and subsequently sintering iron and magnesium powders. The samples were then immersed in an SBL solution at 37 °C. Measurements took place over 23 days. For two samples, measurements were taken each time, while the remaining samples were measured in sequence on their respective days.en
dc.formattextcs
dc.format.extent287-292cs
dc.format.mimetypeapplication/pdfen
dc.identifier.citationProceedings I of the 30st Conference STUDENT EEICT 2024: General papers. s. 287-292. ISBN 978-80-214-6231-1cs
dc.identifier.isbn978-80-214-6231-1
dc.identifier.issn2788-1334
dc.identifier.urihttps://hdl.handle.net/11012/249253
dc.language.isoencs
dc.publisherVysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.relation.ispartofProceedings I of the 30st Conference STUDENT EEICT 2024: General papersen
dc.relation.urihttps://www.eeict.cz/eeict_download/archiv/sborniky/EEICT_2024_sbornik_1.pdfcs
dc.rights© Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.rights.accessopenAccessen
dc.subjectcorrosionen
dc.subjectcorrosion currenten
dc.subjectsimulated body fluiden
dc.subjectsolutionen
dc.subjectoxidationen
dc.titleImpact of the Number of Measurements on Result Distortionen
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
eprints.affiliatedInstitution.departmentFakulta elektrotechniky a komunikačních technologiícs