Comparison of different configurations of Phase Doppler Analyser

dc.contributor.authorZaremba, Matoušcs
dc.contributor.authorMalý, Milancs
dc.contributor.authorJedelský, Jancs
dc.contributor.authorJícha, Miroslavcs
dc.coverage.issue02142cs
dc.coverage.volume114cs
dc.date.issued2016-03-28cs
dc.description.abstractA phase Doppler anemometry (PDA) technique is widely used in experimental fluid mechanics to measure size and velocity of particles in the fluid flow. Even though this method is common in experimental fluid mechanics, there are only few techniques that might serve for the purpose of the evaluation of the PDA system. To examine results of the PDA visualizations techniques are usually used. However, this approach suffers from several aspects. Mainly, it is difficult to determine the exact position of the measurement volume of PDA system. Then it is complicated to determine which particles are passing through the measuring volume. Another way how to examine performance of the PDA system is to use two PDA systems simultaneously. By using one laser for both systems we can avoid previously mentioned aspects. In our experiments, we use fiber based PDA system and classical PDA system both made by Dantec Dynamics. The aim of this paper is to compare results from various configurations and highlight crucial parameters that influence measurements.en
dc.formattextcs
dc.format.extent519-523cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationEPJ Web of Conferences. 2016, vol. 114, issue 02142, p. 519-523.en
dc.identifier.doi10.1051/epjconf/201611402142cs
dc.identifier.issn2100-014Xcs
dc.identifier.orcid0000-0002-1193-519Xcs
dc.identifier.orcid0000-0002-1268-8434cs
dc.identifier.orcid0000-0002-1409-5165cs
dc.identifier.other124260cs
dc.identifier.researcheridAAY-7288-2021cs
dc.identifier.researcheridA-9224-2013cs
dc.identifier.researcheridCVT-7747-2022cs
dc.identifier.scopus57189715785cs
dc.identifier.scopus23090535800cs
dc.identifier.scopus6602494673cs
dc.identifier.urihttp://hdl.handle.net/11012/70014
dc.language.isoencs
dc.publisherEDP Sciencescs
dc.relation.ispartofEPJ Web of Conferencescs
dc.relation.urihttp://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02142/epjconf_efm2016_02142.htmlcs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2100-014X/cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectPhase Doppler analyseren
dc.subjectconfigurationen
dc.subjectcomparisonen
dc.titleComparison of different configurations of Phase Doppler Analyseren
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-124260en
sync.item.dbtypeVAVen
sync.item.insts2025.02.03 15:46:56en
sync.item.modts2025.01.17 15:24:26en
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Energetický ústavcs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
epjconf_efm2016_02142.pdf
Size:
287.26 KB
Format:
Adobe Portable Document Format
Description:
epjconf_efm2016_02142.pdf