Detection of Eccentricity and Broken Rotor Bar Faults by Means of Monitoring of Current and Magnetic Flux Density Spectrums

but.event.date23.04.2015cs
but.event.titleStudent EEICT 2015cs
dc.contributor.authorIshkova, I.
dc.date.accessioned2015-08-25T08:43:09Z
dc.date.available2015-08-25T08:43:09Z
dc.date.issued2015cs
dc.description.abstractIn this paper, faults detection and classification using motor current signature analysis (MCSA) and monitoring of magnetic flux density in air-gap of the machine is presented. A series of simulations using the models of three phase cage induction motor performed in different fault condition, such as static, dynamic and mixed eccentricity and broken rotor bars. Designed models were implemented with the help of finite element method to provide data that makes it possible to diagnose presence of any type of fault, as well as to analyze obtained and calculated results. Models were designed on the basis of characteristics and parameters of real motor. The results are illustrated in the form of graphs that makes visible illustration for effectiveness of the used diagnosis method.en
dc.formattextcs
dc.format.extent610-614cs
dc.format.mimetypeapplication/pdfen
dc.identifier.citationProceedings of the 21st Conference STUDENT EEICT 2015. s. 610-614. ISBN 978-80-214-5148-3cs
dc.identifier.isbn978-80-214-5148-3
dc.identifier.urihttp://hdl.handle.net/11012/43072
dc.language.isoencs
dc.publisherVysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.relation.ispartofProceedings of the 21st Conference STUDENT EEICT 2015en
dc.relation.urihttp://www.feec.vutbr.cz/EEICT/cs
dc.rights© Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologiícs
dc.rights.accessopenAccessen
dc.subjectair-gap eccentricityen
dc.subjectbroken rotor baren
dc.subjectfaultsen
dc.subjectinduction motoren
dc.subjectmotor current signature analysisen
dc.subjectharmonicsen
dc.subjectprincipal spot harmonicsen
dc.subjectcharacteristic frequenciesen
dc.subjectmagnetic flux densityen
dc.titleDetection of Eccentricity and Broken Rotor Bar Faults by Means of Monitoring of Current and Magnetic Flux Density Spectrumsen
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
eprints.affiliatedInstitution.departmentFakulta elektrotechniky a komunikačních technologiícs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
eeict2015-610-ishkova.pdf
Size:
944.08 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: