Comparison of fatigue performance of polyethylene pipe grades in the form of extruded and compression molded specimens

dc.contributor.authorTrávníček, Lukášcs
dc.contributor.authorPoduška, Jancs
dc.contributor.authorKučera, Jaroslavcs
dc.contributor.authorNáhlík, Lubošcs
dc.contributor.authorHutař, Pavelcs
dc.coverage.issue1cs
dc.coverage.volume43cs
dc.date.accessioned2023-03-21T11:54:47Z
dc.date.available2023-03-21T11:54:47Z
dc.date.issued2023-01-13cs
dc.description.abstractDue to the very long operational lifetimes (up to 100 years) of polyethylene pipes, there is a strong demand for accelerated testing of pipe materials to experimentally prove the ability of a certain material to achieve such lifetime. Among the accelerated tests of performance, the cracked round bar (CRB) test is the most convenient. The CRB test takes advantage of cyclic loading that is applied on cylindrical specimens with a circumferential notch in the middle. The specimens are usually manufactured from plates produced by compression molding from the investigated material. However, for polyethylene pipe producers, the possibility of making the specimens by extrusion would save time and lower the costs. This study is dealing with the comparison of CRB test, and a new test carried out on notched pipe samples produced by extrusion. The goal is to investigate the possibility of measuring the performance directly on extruded pipe specimens. The comparison is illustrated on experimental results of several polyethylene pipe grades of PE80, PE100 and PE100RC often used for pipe manufacture.en
dc.formattextcs
dc.format.extent148-153cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationProcedia Structural Integrity. 2023, vol. 43, issue 1, p. 148-153.en
dc.identifier.doi10.1016/j.prostr.2022.12.250cs
dc.identifier.issn2452-3216cs
dc.identifier.orcid0000-0002-5320-4854cs
dc.identifier.orcid0000-0002-1570-2705cs
dc.identifier.other182115cs
dc.identifier.researcheridA-6475-2009cs
dc.identifier.scopus55992861300cs
dc.identifier.scopus22635754000cs
dc.identifier.urihttp://hdl.handle.net/11012/209222
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofProcedia Structural Integritycs
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S2452321622008137cs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2452-3216/cs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/cs
dc.subjectextruded pipe specimensen
dc.subjectSCG resistanceen
dc.subjectpolyethylene pipe lifetimeen
dc.subjectaccelerated testingen
dc.titleComparison of fatigue performance of polyethylene pipe grades in the form of extruded and compression molded specimensen
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-182115en
sync.item.dbtypeVAVen
sync.item.insts2023.10.30 12:59:22en
sync.item.modts2023.10.30 12:15:45en
thesis.grantorVysoké učení technické v Brně. Středoevropský technologický institut VUT. Středoevropský technologický institut VUTcs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1s2.0S2452321622008137main.pdf
Size:
1.08 MB
Format:
Adobe Portable Document Format
Description:
1s2.0S2452321622008137main.pdf