Unsteadiness in Effervescent Sprays: a New Evaluation Method and the Influence of Operational Conditions

dc.contributor.authorJedelský, Jancs
dc.contributor.authorJícha, Miroslavcs
dc.coverage.issue1cs
dc.coverage.volume18cs
dc.date.issued2008-01-01cs
dc.description.abstractA new evaluation method of unsteadiness of the spray generated by an effervescent atomizer is presented. The method is based on measurements of pressure fluctuations in the atomizer mixing chamber. Measurements, made under different atomizer operational conditions, show that the spray unsteadiness depends mainly on gas-to-liquid ratio (GLR). Decrease in GLR causes the spray to become more unsteady. The relation between atomizer internal two-phase flow pattern and the spray unsteadiness is elucidated by visualization of the internal two-phase flow using a digital camera and the use of published two-phase flow maps. Findings of the new method are complemented and confronted with the results obtained by the use of the spray unsteadiness evaluation method of Edwards and Marx.en
dc.description.abstractA new evaluation method of unsteadiness of the spray generated by an effervescent atomizer is presented. The method is based on measurements of pressure fluctuations in the atomizer mixing chamber. Measurements, made under different atomizer operational conditions, show that the spray unsteadiness depends mainly on gas-to-liquid ratio (GLR). Decrease in GLR causes the spray to become more unsteady. The relation between atomizer internal two-phase flow pattern and the spray unsteadiness is elucidated by visualization of the internal two-phase flow using a digital camera and the use of published two-phase flow maps. Findings of the new method are complemented and confronted with the results obtained by the use of the spray unsteadiness evaluation method of Edwards and Marx.en
dc.formattextcs
dc.format.extent49-83cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationATOMIZATION AND SPRAYS. 2008, vol. 18, issue 1, p. 49-83.en
dc.identifier.doi10.1615/AtomizSpr.v18.i1.20cs
dc.identifier.issn1044-5110cs
dc.identifier.orcid0000-0002-1268-8434cs
dc.identifier.orcid0000-0002-1409-5165cs
dc.identifier.other44240cs
dc.identifier.researcheridA-9224-2013cs
dc.identifier.researcheridCVT-7747-2022cs
dc.identifier.scopus23090535800cs
dc.identifier.scopus6602494673cs
dc.identifier.urihttp://hdl.handle.net/11012/138401
dc.language.isoencs
dc.publisherBegell Housecs
dc.relation.ispartofATOMIZATION AND SPRAYScs
dc.relation.urihttp://www.dl.begellhouse.com/journals/6a7c7e10642258cc,7da5e43f06d335eb,4319cefd3bbc5dc2.htmlcs
dc.rights(C) Begell Housecs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1044-5110/cs
dc.subjectSpray unsteadinessen
dc.subjecteffervescent atomizeren
dc.subjectmeasurement methoden
dc.subjecttwo-phase flowen
dc.subjectSpray unsteadiness
dc.subjecteffervescent atomizer
dc.subjectmeasurement method
dc.subjecttwo-phase flow
dc.titleUnsteadiness in Effervescent Sprays: a New Evaluation Method and the Influence of Operational Conditionsen
dc.title.alternativeUnsteadiness in Effervescent Sprays: a New Evaluation Method and the Influence of Operational Conditionsen
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionacceptedVersionen
sync.item.dbidVAV-44240en
sync.item.dbtypeVAVen
sync.item.insts2025.10.14 14:52:11en
sync.item.modts2025.10.14 10:28:17en
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Energetický ústavcs

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
unsteadinessineffervescentsprays_vut.pdf
Size:
608.2 KB
Format:
Adobe Portable Document Format
Description:
unsteadinessineffervescentsprays_vut.pdf