Hydrothermal performance of wooden beam on solid masonry with capillary-active internal insulation.
dc.contributor.author | Sukop, Lukáš | cs |
dc.contributor.author | Ostrý, Milan | cs |
dc.coverage.issue | 1 | cs |
dc.coverage.volume | 550 | cs |
dc.date.accessioned | 2025-02-03T15:37:52Z | |
dc.date.available | 2025-02-03T15:37:52Z | |
dc.date.issued | 2024-07-16 | cs |
dc.description.abstract | With the increasing requirements for the energy performance of buildings, there is a demand for internal insulation systems in buildings where it is not possible to apply an external insulation system for legislative reasons. Currently, there has been an upsurge in the development of diffusion-open insulation materials whose properties can compensate for the risks of damage to solid masonry walls insulated with traditional diffusion-closed internal insulation systems. The properties of diffusion-open systems are already well known. This paper focuses on the simulation of the thermal moisture behaviour of a detail of a timber beam embedment in a wall with capillary active thermal insulation in cold climatic conditions of Central Europe. | en |
dc.format | text | cs |
dc.format.extent | 1-15 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | E3S Web of Conferences. 2024, vol. 550, issue 1, p. 1-15. | en |
dc.identifier.doi | 10.1051/e3sconf/202455001036 | cs |
dc.identifier.issn | 2267-1242 | cs |
dc.identifier.orcid | 0000-0002-6712-912X | cs |
dc.identifier.other | 189540 | cs |
dc.identifier.researcherid | A-2660-2016 | cs |
dc.identifier.uri | https://hdl.handle.net/11012/250013 | |
dc.language.iso | en | cs |
dc.publisher | EDP Sciences | cs |
dc.relation.ispartof | E3S Web of Conferences | cs |
dc.relation.uri | https://www.e3s-conferences.org/articles/e3sconf/abs/2024/80/e3sconf_ys2024_01036/e3sconf_ys2024_01036.html | cs |
dc.rights | Creative Commons Attribution 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/2267-1242/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | Interior insulation | en |
dc.subject | Capillary active | en |
dc.subject | Wooden beam | en |
dc.subject | Hydrothermal performance | en |
dc.title | Hydrothermal performance of wooden beam on solid masonry with capillary-active internal insulation. | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-189540 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 16:37:52 | en |
sync.item.modts | 2025.02.03 16:33:13 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Ústav pozemního stavitelství | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- e3sconf_ys2024_01036.pdf
- Size:
- 5.2 MB
- Format:
- Adobe Portable Document Format
- Description:
- file e3sconf_ys2024_01036.pdf