Load Frequency Control of HVDC Link Interconnected Power System Using Genetic Algorithm

dc.contributor.authorChanana, Saurabh
dc.contributor.authorKumar, Saurabh
dc.coverage.issue1cs
dc.coverage.volume25cs
dc.date.accessioned2020-05-05T07:21:10Z
dc.date.available2020-05-05T07:21:10Z
dc.date.issued2019-06-24cs
dc.description.abstractAdvances in power electronics have improved grid support functions such as tie-line power control and frequency control, making renewable generation and High Voltage DC (HVDC) links more common in power system applications. Load Frequency Control (LFC) systems handle the complex interactions between the distributed generator and the control area with the HVDC link. In this work, LFC of a two-zone system including parallel AC/DC transmission links has been analysed. The parameters of this system are optimised using advanced genetic algorithm resulting in improved performance of system in terms of reduction in peak overshoots and settling time of frequency measurement, tie line power flow and area control error signals in an interconnected power system. The advantage of having parallel HVDC links is also demonstrated when performance is compared to system interconnected with only AC tie line.en
dc.formattextcs
dc.format.extent131-138cs
dc.format.mimetypeapplication/pdfen
dc.identifier.citationMendel. 2018 vol. 25, č. 1, s. 131-138. ISSN 1803-3814cs
dc.identifier.doi10.13164/mendel.2019.1.131en
dc.identifier.issn2571-3701
dc.identifier.issn1803-3814
dc.identifier.urihttp://hdl.handle.net/11012/186990
dc.language.isoencs
dc.publisherInstitute of Automation and Computer Science, Brno University of Technologycs
dc.relation.ispartofMendelcs
dc.relation.urihttps://mendel-journal.org/index.php/mendel/article/view/89cs
dc.rightsCreative Commons Attribution-NonCommercial-ShareAlike 4.0 International licenseen
dc.rights.accessopenAccessen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0en
dc.subjectfrequency measurementen
dc.subjecta utomatic generation controlen
dc.subjectload frequency controlen
dc.subjectHVDC interconnected systemen
dc.subjecttie line poweren
dc.subjectarea control erroren
dc.titleLoad Frequency Control of HVDC Link Interconnected Power System Using Genetic Algorithmen
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
eprints.affiliatedInstitution.facultyFakulta strojního inženýrstvícs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019-1-131.pdf
Size:
1.89 MB
Format:
Adobe Portable Document Format
Description:
Collections