Compatibility of Phase Change Materials and Metals:Experimental Evaluation Based on the Corrosion Rate

dc.contributor.authorOstrý, Milancs
dc.contributor.authorBantová, Sylvacs
dc.contributor.authorStruhala, Karelcs
dc.coverage.issue12cs
dc.coverage.volume25cs
dc.date.issued2020-06-18cs
dc.description.abstractThe construction and maintenance of building stock is responsible for approximately 36% of all CO(2)emissions in the European Union. One of the possibilities of how to achieve high energy-efficient and decarbonized building stock is the integration of renewable energy sources (RES) in building energy systems that contain efficient energy storage capacity. Phase Change Materials (PCMs) are latent heat storage media with a high potential of integration in building structures and technical systems. Their solid-liquid transition is specifically utilized for thermal energy storage in building applications. The typically quite old example is the use of ice that serves as long-term storage of cold. Large pieces of ice cut in winter were stored in heavily insulated spaces and prepared for cooling of food or beverages in summer. In the contemporary use of the principle, the PCMs for building applications and tested in this study must have a melting range close to the desired temperature in the occupied rooms. As the PCMs need to be encapsulated, several types of metal containers have been developed and tested for their thermal conductivity and resistance to mechanical damage, which enhances the performance of these so-called latent heat thermal energy storage (LHTES) systems. Long-term compatibility of metals with PCMs depends, i.e., on the elimination of an undesirable interaction between the metal and the specific PCM. Heat storage medium must be reliably sealed in a metal container, especially if the LHTES is integrated into systems where PCM leaks can negatively affect human health (e.g., domestic hot water tanks). The aim of this study is to evaluate the interactions between the selected commercially available organic (Linpar 17 and 1820) and inorganic (Rubitherm SP22 and SP25) PCMs and metals widely used for PCM encapsulation (aluminum, brass, carbon steel, and copper). The evaluation is based on the calculation of the corrosion rate (CR), and the gravimetric method is used for the determination of the weight variations of the metal samples. The results show good compatibility for all metals with organic PCMs, which is demonstrated by a mass loss as low as 2.1 mg in case of carbon steel immersed in Linpar 1820 for 12 weeks. The exposure of metals to organic PCMs also did not cause any visual changes on the surface except for darker stains, and tarnishing occurred on the copper samples. More pronounced changes were observed in metal samples immersed in inorganic PCMs. The highest CR values were calculated for carbon steel exposed to inorganic PCM Rubitherm SP25 (up to 13.897 mg center dot cm(-2)center dot year(-1)). The conclusion of the study is that aluminum is the most suitable container material for the tested PCMs as it shows the lowest mass loss and minimal visual changes on the surface after prolonged exposure to the selected PCMs.en
dc.description.abstractThe construction and maintenance of building stock is responsible for approximately 36% of all CO(2)emissions in the European Union. One of the possibilities of how to achieve high energy-efficient and decarbonized building stock is the integration of renewable energy sources (RES) in building energy systems that contain efficient energy storage capacity. Phase Change Materials (PCMs) are latent heat storage media with a high potential of integration in building structures and technical systems. Their solid-liquid transition is specifically utilized for thermal energy storage in building applications. The typically quite old example is the use of ice that serves as long-term storage of cold. Large pieces of ice cut in winter were stored in heavily insulated spaces and prepared for cooling of food or beverages in summer. In the contemporary use of the principle, the PCMs for building applications and tested in this study must have a melting range close to the desired temperature in the occupied rooms. As the PCMs need to be encapsulated, several types of metal containers have been developed and tested for their thermal conductivity and resistance to mechanical damage, which enhances the performance of these so-called latent heat thermal energy storage (LHTES) systems. Long-term compatibility of metals with PCMs depends, i.e., on the elimination of an undesirable interaction between the metal and the specific PCM. Heat storage medium must be reliably sealed in a metal container, especially if the LHTES is integrated into systems where PCM leaks can negatively affect human health (e.g., domestic hot water tanks). The aim of this study is to evaluate the interactions between the selected commercially available organic (Linpar 17 and 1820) and inorganic (Rubitherm SP22 and SP25) PCMs and metals widely used for PCM encapsulation (aluminum, brass, carbon steel, and copper). The evaluation is based on the calculation of the corrosion rate (CR), and the gravimetric method is used for the determination of the weight variations of the metal samples. The results show good compatibility for all metals with organic PCMs, which is demonstrated by a mass loss as low as 2.1 mg in case of carbon steel immersed in Linpar 1820 for 12 weeks. The exposure of metals to organic PCMs also did not cause any visual changes on the surface except for darker stains, and tarnishing occurred on the copper samples. More pronounced changes were observed in metal samples immersed in inorganic PCMs. The highest CR values were calculated for carbon steel exposed to inorganic PCM Rubitherm SP25 (up to 13.897 mg center dot cm(-2)center dot year(-1)). The conclusion of the study is that aluminum is the most suitable container material for the tested PCMs as it shows the lowest mass loss and minimal visual changes on the surface after prolonged exposure to the selected PCMs.en
dc.formattextcs
dc.format.extent1-15cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationMOLECULES. 2020, vol. 25, issue 12, p. 1-15.en
dc.identifier.doi10.3390/molecules25122823cs
dc.identifier.issn1420-3049cs
dc.identifier.orcid0000-0002-6712-912Xcs
dc.identifier.orcid0000-0001-8926-8406cs
dc.identifier.orcid0000-0003-1076-3450cs
dc.identifier.other169220cs
dc.identifier.researcheridA-2660-2016cs
dc.identifier.scopus57202680708cs
dc.identifier.scopus55597153500cs
dc.identifier.urihttp://hdl.handle.net/11012/196662
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofMOLECULEScs
dc.relation.urihttps://www.mdpi.com/1420-3049/25/12/2823cs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1420-3049/cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectphase change materials (PCMs)en
dc.subjectmetalsen
dc.subjectcontaineren
dc.subjectlatent heat storageen
dc.subjectcorrosionen
dc.subjectphase change materials (PCMs)
dc.subjectmetals
dc.subjectcontainer
dc.subjectlatent heat storage
dc.subjectcorrosion
dc.titleCompatibility of Phase Change Materials and Metals:Experimental Evaluation Based on the Corrosion Rateen
dc.title.alternativeCompatibility of Phase Change Materials and Metals:Experimental Evaluation Based on the Corrosion Rateen
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-169220en
sync.item.dbtypeVAVen
sync.item.insts2025.10.14 14:14:46en
sync.item.modts2025.10.14 09:49:50en
thesis.grantorVysoké učení technické v Brně. Fakulta stavební. Ústav pozemního stavitelstvícs
thesis.grantorVysoké učení technické v Brně. Fakulta stavební. Centrum AdMaS - VP2 - KCEcs

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
molecules2502823.pdf
Size:
3.81 MB
Format:
Adobe Portable Document Format
Description:
molecules2502823.pdf