Registration of retinal sequences from new video-ophthalmoscopic camera
dc.contributor.author | Kolář, Radim | cs |
dc.contributor.author | Tornow, Ralf-Peter | cs |
dc.contributor.author | Odstrčilík, Jan | cs |
dc.contributor.author | Labounková, Ivana | cs |
dc.coverage.issue | 57 | cs |
dc.coverage.volume | 15 | cs |
dc.date.issued | 2016-05-20 | cs |
dc.description.abstract | Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. | en |
dc.format | text | cs |
dc.format.extent | 1-17 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | BIOMED ENG ONLINE. 2016, vol. 15, issue 57, p. 1-17. | en |
dc.identifier.doi | 10.1186/s12938-016-0191-0 | cs |
dc.identifier.issn | 1475-925X | cs |
dc.identifier.orcid | 0000-0002-0469-6397 | cs |
dc.identifier.orcid | 0000-0001-7053-6183 | cs |
dc.identifier.other | 125580 | cs |
dc.identifier.researcherid | C-8547-2014 | cs |
dc.identifier.researcherid | A-2237-2016 | cs |
dc.identifier.scopus | 35753651000 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/60633 | |
dc.language.iso | en | cs |
dc.publisher | BioMed Central | cs |
dc.relation.ispartof | BIOMED ENG ONLINE | cs |
dc.relation.uri | http://biomedical-engineering-online.biomedcentral.com/articles/10.1186/s12938-016-0191-0 | cs |
dc.rights | Creative Commons Attribution 4.0 International | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1475-925X/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | Retinal imaging | en |
dc.subject | Video-ophthalmoscopy | en |
dc.subject | Image registration | en |
dc.subject | Tracking | en |
dc.title | Registration of retinal sequences from new video-ophthalmoscopic camera | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-125580 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:40:02 | en |
sync.item.modts | 2025.01.17 19:35:11 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Kolar_BMEOnline_Final.pdf
- Size:
- 3 MB
- Format:
- Adobe Portable Document Format
- Description:
- Kolar_BMEOnline_Final.pdf