Termální degradace hyaluronanu

but.committeeprof. Ing. Miloslav Pekař, CSc. (předseda) prof. Ing. Michal Čeppan, CSc. (místopředseda) doc. Ing. Irena Kratochvílová, Ph.D. (člen) doc. Ing. Marián Lehocký, Ph.D. (člen) prof. Ing. Oldřich Zmeškal, CSc. (člen) prof. Ing. Michal Veselý, CSc. (člen)cs
but.defencePekař: v jaké atmosféře byla prováděna termická analýza Veselý: k čemu je vztažena relativní hmotnostcs
but.jazykčeština (Czech)
but.programSpotřební chemiecs
but.resultpráce byla úspěšně obhájenacs
dc.contributor.advisorChytil, Martincs
dc.contributor.authorŠimáčková, Marcelacs
dc.contributor.refereeDavid, Jancs
dc.date.accessioned2019-04-04T02:56:13Z
dc.date.available2019-04-04T02:56:13Z
dc.date.created2016cs
dc.description.abstractTepelná stabilita a degradace hyaluronanu (HA) byla v rámci této diplomové práce zkoumána u HA s molekulovou hmotností 90–130 kDa a u HA s molekulovou hmotností 1 500–1 750 kDa. K výzkumu byly použity metody reologie, SEC-MALLS, TGA a DSC. Nízkomolekulový HA byl podroben zkoumání časové závislosti degradace, kdy byl před samotnou přípravou roztoků sušen při teplotě 90 °C po dobu 30 minut a 60 minut. U vysokomolekulového HA byla zkoumána nejen časová, ale i teplotní závislost degradace. V případě zkoumání časové závislosti degradace byl vysokomolekulový HA před přípravou roztoků sušen při teplotě 75 °C v časovém rozmezí od 15 minut do 120 minut. Při přípravě roztoků pro zjištění teplotní závislosti degradace byl pak vysokomolekulový HA sušen po dobu 30 minut v rozmezí teplot od 60 °C do 90 °C. U nízkomolekulového HA byla prokázána tepelná stabilita, nedocházelo tedy k poklesu molekulové hmotnosti a roztoky nevykazovaly výrazný pokles viskozity. U vysokomolekulového HA tepelná stabilita prokázána nebyla, k degradaci vlivem teploty sušení, ale i času sušení docházelo, což se projevilo výrazným poklesem molekulové hmotnosti a viskozity roztoků. Zatímco v případě použití teploty sušení 60 °C došlo k poklesu molekulové hmotnosti přibližně o 5 %, při teplotě sušení 90 °C se molekulová hmotnost snížila přibližně o 20 % oproti nesušenému HA. Z tohoto důvodu byl vysokomolekulový HA dále zkoumán i pomocí metod TGA, kde bylo sledováno snížení vlhkosti vzorků HA v závislosti na teplotě sušení, a DSC, kde bylo cílem zjistit teploty, při kterých dochází k odpaření vlhkosti obsažené ve vzorku HA v závislosti na jeho formě (nesušeného HA, sušeného HA a lyofilizovaného HA) a dále teplo potřebné k odpaření vlhkosti ze vzorku HA. Na závěr tohoto výzkumu byly získané výsledky u vysokomolekulového HA porovnány s výsledky jiného procesu sušení – lyofilizací, která se ukázala jako velmi šetrná metoda sušení, protože k poklesu molekulové hmotnosti u lyofilizovaného HA oproti nesušenému HA téměř nedocházelo.cs
dc.description.abstractThis diploma thesis investigated thermal stability and the degradation of hyaluronan (HA) in HA with a molecular mass of 90–130 kDa and in HA with a molecular mass of 1 500–1 750 kDa. The following methods were used for the research: rheology, SEC-MALLS, TGA and DSC. Low-molecular HA was subject to time dependency of degradation investigation, where it was dried at a temperature of 90 °C for a period of 30 minutes and 60 minutes prior to the preparation of the solutions itself. High-molecular HA was investigated not only from the point of view of time but from the point of view of temperature dependency of degradation as well. In the case of investigating the time dependency of degradation, high-molecular HA was dried at a temperature of 75 °C at a time range from 15 minutes to 120 minutes prior to the preparation of the solutions. During the preparation of the solutions for discovering the temperature dependency of degradation, the high-molecular HA was then dried for a period of 30 minutes at a temperature range from 60 °C to 90 °C. For low-molecular HA, thermal stability was proven. Therefore, there is no decrease in the molecular mass and the solutions did not demonstrate a significant decrease of viscosity. For high-molecular HA, thermal stability was not proven. Degradation due to the temperature of drying as well as the time of drying occurred, which was demonstrated by a significant decrease in molecular mass and viscosity of the solutions. While in the case of using a drying temperature of 60 °C, a decrease in the molecular mass occurred by approximately 5 %, the molecular mass decreased by approximately 20 % at a drying temperature of 90 °C compared to undried HA. Due to this reason, high-molecular HA was also further investigated by means of the TGA method, where the decrease of humidity of HA samples in relation to the drying temperature was observed. The DSC method was also used. The objective of the DSC method was to find out temperatures, at which evaporation of humidity contained in an HA sample in relation to its form (undried HA, dried HA and lyophilized HA) occurs. This method further finds out the heat necessary to evaporate humidity from an HA sample. To conclude this research, the results obtained for high-molecular HA were compared with the results of other drying processes – lyophilized proved to be a very gentle drying method because a decrease in the molecular mass for lyophilized HA compared with undried HA almost did not occur.en
dc.description.markAcs
dc.identifier.citationŠIMÁČKOVÁ, M. Termální degradace hyaluronanu [online]. Brno: Vysoké učení technické v Brně. Fakulta chemická. 2016.cs
dc.identifier.other88187cs
dc.identifier.urihttp://hdl.handle.net/11012/58305
dc.language.isocscs
dc.publisherVysoké učení technické v Brně. Fakulta chemickács
dc.rightsStandardní licenční smlouva - přístup k plnému textu bez omezenícs
dc.subjecthyaluronancs
dc.subjecttepelná degradacecs
dc.subjecttepelná stabilitacs
dc.subjectmolekulová hmotnostcs
dc.subjectviskozitacs
dc.subjectSEC-MALLScs
dc.subjectreologiecs
dc.subjecttermická analýzacs
dc.subjecthyaluronanen
dc.subjectthermal degradationen
dc.subjectthermal stabilityen
dc.subjectmolecular massen
dc.subjectviscosityen
dc.subjectSEC-MALLSen
dc.subjectrheologyen
dc.subjectthermal analysisen
dc.titleTermální degradace hyaluronanucs
dc.title.alternativeThermal degradation of hyaluronanen
dc.typeTextcs
dc.type.drivermasterThesisen
dc.type.evskpdiplomová prácecs
dcterms.dateAccepted2016-06-01cs
dcterms.modified2016-06-02-11:08:47cs
eprints.affiliatedInstitution.facultyFakulta chemickács
sync.item.dbid88187en
sync.item.dbtypeZPen
sync.item.insts2021.11.12 20:09:23en
sync.item.modts2021.11.12 19:01:20en
thesis.disciplineSpotřební chemiecs
thesis.grantorVysoké učení technické v Brně. Fakulta chemická. Ústav fyzikální a spotřební chemiecs
thesis.levelInženýrskýcs
thesis.nameIng.cs
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
final-thesis.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format
Description:
final-thesis.pdf
Loading...
Thumbnail Image
Name:
review_88187.html
Size:
15.75 KB
Format:
Hypertext Markup Language
Description:
review_88187.html
Collections