Influence in connection of a vapor barrier in critical detail of composite construction
| dc.contributor.author | Pospíšil, Jaroslav | cs |
| dc.contributor.author | Šuhajda, Karel | cs |
| dc.coverage.issue | 1 | cs |
| dc.coverage.volume | 195 | cs |
| dc.date.issued | 2016-11-24 | cs |
| dc.description.abstract | Influence of connection vapor barrier in a critical detail of composite structures is directed to the humidity temperature evaluation of a design detail, focusing on the risk of mold growth. Detail corner of the building is elected with a variation of the connection of vapor barrier on the concrete skeleton. The thesis describes the course of moisture in those points of structure describing the possibility of the occurrence and growth of fungus. | en |
| dc.description.abstract | Influence of connection vapor barrier in a critical detail of composite structures is directed to the humidity temperature evaluation of a design detail, focusing on the risk of mold growth. Detail corner of the building is elected with a variation of the connection of vapor barrier on the concrete skeleton. The thesis describes the course of moisture in those points of structure describing the possibility of the occurrence and growth of fungus. | en |
| dc.format | text | cs |
| dc.format.extent | 88-95 | cs |
| dc.format.mimetype | application/pdf | cs |
| dc.identifier.citation | Procedia Engineering. 2016, vol. 195, issue 1, p. 88-95. | en |
| dc.identifier.doi | 10.1016/j.proeng.2017.04.528 | cs |
| dc.identifier.isbn | 978-1-5108-4504-6 | cs |
| dc.identifier.issn | 1877-7058 | cs |
| dc.identifier.orcid | 0000-0001-6525-6662 | cs |
| dc.identifier.orcid | 0000-0001-7842-6966 | cs |
| dc.identifier.other | 131821 | cs |
| dc.identifier.researcherid | AAD-6344-2019 | cs |
| dc.identifier.scopus | 54403777800 | cs |
| dc.identifier.uri | http://hdl.handle.net/11012/204229 | |
| dc.language.iso | en | cs |
| dc.publisher | Elsevier | cs |
| dc.relation.ispartof | Procedia Engineering | cs |
| dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S1877705817320805 | cs |
| dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | cs |
| dc.rights.access | openAccess | cs |
| dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1877-7058/ | cs |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | cs |
| dc.subject | Composite structures | en |
| dc.subject | vapor barrier | en |
| dc.subject | humidity | en |
| dc.subject | temperature | en |
| dc.subject | mold grow | en |
| dc.subject | Composite structures | |
| dc.subject | vapor barrier | |
| dc.subject | humidity | |
| dc.subject | temperature | |
| dc.subject | mold grow | |
| dc.title | Influence in connection of a vapor barrier in critical detail of composite construction | en |
| dc.title.alternative | Influence in connection of a vapor barrier in critical detail of composite construction | en |
| dc.type.driver | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
| sync.item.dbid | VAV-131821 | en |
| sync.item.dbtype | VAV | en |
| sync.item.insts | 2025.10.14 14:16:00 | en |
| sync.item.modts | 2025.10.14 10:18:18 | en |
| thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Ústav pozemního stavitelství | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1s2.0S1877705817320805main.pdf
- Size:
- 945.24 KB
- Format:
- Adobe Portable Document Format
- Description:
- 1s2.0S1877705817320805main.pdf
