Measurement of the runoff coefficient of extensive greenroof
dc.contributor.author | Vystrčil, Jan | cs |
dc.contributor.author | Nespěšný, Ondřej | cs |
dc.contributor.author | Šuhajda, Karel | cs |
dc.contributor.author | Bečkovský, David | cs |
dc.contributor.author | Selník, Petr | cs |
dc.coverage.issue | 012934 | cs |
dc.coverage.volume | 1209 | cs |
dc.date.issued | 2021-12-21 | cs |
dc.description.abstract | Describes the procedure of experimental measurement of the runoff coefficient C, both of individual layers and the entire composition extensive green roofs. Experimental measurements make it possible to determine the reference behaviour of runoff characteristics, namely runoff coefficient C, with emphasis on the simulation of the real behaviour of extensive green roofs. The aim is an elementary description of the structural and physical behaviour of extensive green roofs. For the needs of experimental measurement, the dimensional and shape limits of test specimens are described, the conditions for conditioning of individual specimens, the boundary conditions of execution and individual steps of the experiment. Then is specified the method of evaluation and subsequent verification of measured data. The result of the experimental measurement is the amount of drained water from the tested specimens of the extensive green roof at time t, which shows a nonlinear behaviour. From the set of measured data, it is then possible to predict the behaviour of extensive green roofs in real conditions and to determine the runoff coefficient C of the tested specimens. These data represent reference values for the subsequent design of sub-elements and structures of buildings. | en |
dc.format | text | cs |
dc.format.extent | 1-6 | cs |
dc.format.mimetype | application/pdf | cs |
dc.identifier.citation | IOP Conference Series: Materials Science and Engineering. 2021, vol. 1209, issue 012934, p. 1-6. | en |
dc.identifier.doi | 10.1088/1757-899X/1209/1/012034 | cs |
dc.identifier.issn | 1757-899X | cs |
dc.identifier.orcid | 0000-0001-5704-3923 | cs |
dc.identifier.orcid | 0000-0002-8505-9575 | cs |
dc.identifier.orcid | 0000-0001-7842-6966 | cs |
dc.identifier.orcid | 0000-0002-5816-0766 | cs |
dc.identifier.orcid | 0000-0001-8586-9749 | cs |
dc.identifier.other | 175935 | cs |
dc.identifier.researcherid | AAD-6344-2019 | cs |
dc.identifier.researcherid | AAZ-3333-2021 | cs |
dc.identifier.scopus | 54403777800 | cs |
dc.identifier.uri | http://hdl.handle.net/11012/204002 | |
dc.language.iso | en | cs |
dc.publisher | IOP Publishing | cs |
dc.relation.ispartof | IOP Conference Series: Materials Science and Engineering | cs |
dc.relation.uri | https://doi.org/10.1088/1757-899X/1209/1/012034 | cs |
dc.rights | Creative Commons Attribution 3.0 Unported | cs |
dc.rights.access | openAccess | cs |
dc.rights.sherpa | http://www.sherpa.ac.uk/romeo/issn/1757-899X/ | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | cs |
dc.subject | experimental measurement | en |
dc.subject | runoff coefficient | en |
dc.subject | green roof | en |
dc.title | Measurement of the runoff coefficient of extensive greenroof | en |
dc.type.driver | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
sync.item.dbid | VAV-175935 | en |
sync.item.dbtype | VAV | en |
sync.item.insts | 2025.02.03 15:44:56 | en |
sync.item.modts | 2025.01.17 15:21:15 | en |
thesis.grantor | Vysoké učení technické v Brně. Fakulta stavební. Ústav pozemního stavitelství | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Vystrcil_2021.pdf
- Size:
- 787.5 KB
- Format:
- Adobe Portable Document Format
- Description:
- Vystrcil_2021.pdf