Influence of experimental conditions on localized surface plasmon resonances measurement by electron energy loss spectroscopy

Loading...
Thumbnail Image

Authors

Horák, Michal
Šikola, Tomáš

Advisor

Referee

Mark

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier
Altmetrics

Abstract

Scanning transmission electron microscopy (STEM) combined with electron energy loss spectroscopy (EELS) has become a standard technique to map localized surface plasmon resonances with a nanometer spatial and a sufficient energy resolution over the last 15 years. However, no experimental work discussing the influence of experimental conditions during the measurement has been published up to now. We present an experimental study of the influence of the primary beam energy and the collection semi-angle on the plasmon resonances measurement by STEM-EELS. To explore the influence of these two experimental parameters we study a series of gold rods and gold bow-tie and diabolo antennas. We discuss the impact on experimental characteristics which are important for successful detection of the plasmon peak in EELS, namely: the intensity of plasmonic signal, the signal to background ratio, and the signal to zero-loss peak ratio. We found that the primary beam energy should be high enough to suppress the scattering in the sample and at the same time should be low enough to avoid the appearance of relativistic effects. Consequently, the best results are obtained using a medium primary beam energy, in our case 120 keV, and an arbitrary collection semi-angle, as it is not a critical parameter at this primary beam energy. Our instructive overview will help microscopists in the field of plasmonics to arrange their experiments.
Scanning transmission electron microscopy (STEM) combined with electron energy loss spectroscopy (EELS) has become a standard technique to map localized surface plasmon resonances with a nanometer spatial and a sufficient energy resolution over the last 15 years. However, no experimental work discussing the influence of experimental conditions during the measurement has been published up to now. We present an experimental study of the influence of the primary beam energy and the collection semi-angle on the plasmon resonances measurement by STEM-EELS. To explore the influence of these two experimental parameters we study a series of gold rods and gold bow-tie and diabolo antennas. We discuss the impact on experimental characteristics which are important for successful detection of the plasmon peak in EELS, namely: the intensity of plasmonic signal, the signal to background ratio, and the signal to zero-loss peak ratio. We found that the primary beam energy should be high enough to suppress the scattering in the sample and at the same time should be low enough to avoid the appearance of relativistic effects. Consequently, the best results are obtained using a medium primary beam energy, in our case 120 keV, and an arbitrary collection semi-angle, as it is not a critical parameter at this primary beam energy. Our instructive overview will help microscopists in the field of plasmonics to arrange their experiments.

Description

Citation

ULTRAMICROSCOPY. 2020, vol. 216, issue 1, p. 1-9.
https://www.sciencedirect.com/science/article/pii/S0304399120300504

Document type

Peer-reviewed

Document version

submittedVersion

Date of access to the full text

Language of document

en

Study field

Comittee

Date of acceptance

Defence

Result of defence

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Creative Commons Attribution 4.0 International
Citace PRO